WIRING DIAGRAMS

Installation guide FFB brake motors

5286 en - 2017.09 / c

en

➀ 

and 

➁ 

Brake motor: wiring diagram under the TB cover

DEBRANCHER LE BLOC REDRESSEUR

POUR ESSAI D'ISOLEMENT OU DIELECTRIQUE

DISCONNECT THE RECTIFIER CELL

 WHEN

TESTING FOR CURRENT INSULA

TION OR DIELECTRIC.

634118 fr-en/f

IMPORT

ANT

1 vitesse - 2 tensions (rapport 1.732) 1 bobinage

1 speed- 2 voltage (ratio 1.732) 1 winding

W2 T6

U1 T1

U2 T4

V1 T2

V2 T5

W1 T3

W2 T6

U1 T1

U2 T4

V1 T2

V2  T5

W1 T3

**S08

**S08

**débrancher les shunts dans le cas

  d'une alimentation séparée
**disconnect the shunts

  for separate power supply

(A) coupure sur continu : temps de réponse réduit

obligatoire en levage : ENLEVER LE STRAP

(A) DC braking : shorter response time

Mandatory for lifting application : REMOVE WIRE

Schéma de branchement frein / Brake connection diagram

Alimentation

Power supply

Bobine

Coil

400V AC

230V AC

230V AC

127V AC

180V DC

100V DC

180V DC

100V DC

Câblage*

Cabling*

2

1

Bobine/coil

Alimentation

Power supply

S O8

~

~

~

_

-

+

++

(A)

±15%

2

1

*suivant alimentation et bobine

* according power supply and coil

*suivant alimentation et bobine

* according power supply and coil

Check the brake wiring according to the power 

supply

3.2 - 180 VDC brake coil 

(power supply 500V maxi)

(A) coupure sur continu : temps de réponse réduit

obligatoire en Usage Levage : ENLEVER LE STRAP

(A)

 DC braking : shorter response time

Mandatory for lifting application : REMOVE WIRE

Alimentation

Power supply

Bobine

Coil

400V AC

230V AC

230V AC

127V AC

180V DC

100V DC

180V DC

100V DC

Câblage*

Cabling*

2

1

Bobine / 

coil

Alimentation

Power supply

S O8

~

~

~

_

-

+

++

(A)

±15%

2

1

*suivant alimentation et bobine

* according power supply and coil

*suivant alimentation et bobine

* according power supply and coil

 20 VDC brake coil:

Wiring diagram for the separate 24 V power supply option 

(frame sizes 71 to 180)

IMPORTANT

Débrancher le bloc redresseur

pour essai d’isolement ou diélectrique

Disconnect the rectifier cell when testing

for current insulation or dielectric

Schéma de branchement

Connection diagram

FREIN - BRAKE

Coupure sur le continu

(obligatoire en levage)

ENLEVER LE STRAP

Connection for shorter

response time

(mandatory for hoisting

)

REMOVE THE STRAP

24V

20V

E

F

S O6

~

~

~

-

+

 180 VDC brake coil:

2-speed motor, 2 windings, 1 voltage, built-in power supply

IMPORTANT

Débrancher le bloc redresseur

pour essai d’isolement ou diélectrique

Disconnect the rectifier cell when testing

for current insulation or dielectric

1U2 2U2 1 U1

+

-

2

SO3

Bobine/coil

350V AC à/to 460V AC

180V DC

200V AC à/to 265V AC

100V DC

3.3 - Speed and position encoders

 

Standard incremental encoder

: 5V DC (TTL) or 11/30V

(HTL) 1024 pts/rev or 4096 pts/rev - Separate supply brake

Terminal  No.      

Connection

Colour

1

0V

White

2

+VCC

Brown

3

A

Green

4

B

Yellow

5

0

Grey

6

A

Pink

7

B

Blue

8

0

Red

9

Not connected (free)

-

10

Mass

-

11

Mass

-

12

Mass

-

 

View of M23 male connector base at the encoder end

Standard absolute encoder

: 10/30 VDC, SinCos SSI multi-

turn - 

Brake with separate power supply

 

Terminal

No.       Connection

Function

1

0V

Coder mass

2

+VCC

Supply voltage

3

Clock+

Clock signal

4

Clock-

Clock signal

5

Data+

Data signal

6

Data-

Data signal

7

SET

Current position defined at 0 (reset)

8

DIR

Clockwise or anti-clockwise counting 

direction

9

A

Sine output (incremental)

10

A

Sine output (incremental)

11

B

Cosine output (incremental)

12

B

Cosine output (incremental)

-  Switch  off  the  power  supply  before  performing  any 

connection operations (connection or disconnection, with or 

without connectors) at the encoder or cabinet end.

-  For  reasons  of  synchronization,  power  up  and  power 

down  the  encoders  and  any  associated  electronic  devices 

simultaneously.  On  the  first  power-up,  check  that  the 

“” terminal is supplying the required voltage before 

connection.

- For the supply, use stabilized power supplies.

Power supplies via transformers providing 5 V (or 24 V) rms, 

followed by rectifiers and smoothing capacitors, must not be 

used, as in reality the resulting DC voltages obtained are:

For 5 V: 5x√2 = 7.07 V

For 24 V: 24x√2 = 33.936 V

Brake

Содержание LEROY-SOMER FFB

Страница 1: ...en Installation guide Brake motors FFB Before any intervention or operation for preventive or corrective maintenance please download NECESSARILY the update version of Maintenance guide reference 5287...

Страница 2: ...is compatible with its environment before its installation and also throughout its life The following preliminary precautions must be taken before working on any stationary device Mains voltage disco...

Страница 3: ...iable to be changed without notice CONTENTS 1 RECEIPT 4 1 1 Identification 4 1 2 Storage 4 2 RECOMMENDATIONS 4 2 1 Commissioning 4 2 2 Mechanical installation 4 2 2 1 Brake with options 5 2 3 Electric...

Страница 4: ...d check the winding insulation resistance phase earth resistance higher than 10 M Drain any condensation water 2 RECOMMENDATIONS 2 1 Commissioning The brake motor is designed to operate at the speeds...

Страница 5: ...th a wear indicator while the brake is supplied with power the armature actuates a microswitch discrete fixed on the yoke If the brake lining is worn 0 6 mm the microswitch is actuated and informs the...

Страница 6: ...e gland Cable gland type Standard cable gland polyamide Cable size Tightening torque Min cable mm Max cable mm Gland and body N m ISO 20a 5 12 2 ISO 20 7 14 2 ISO 25 9 18 3 FLS ES series Brass anchori...

Страница 7: ...ect the rectifier cell when testing for current insulation or dielectric Sch ma de branchement Connection diagram FREIN BRAKE Coupure sur le continu obligatoire en levage ENLEVER LE STRAP Connection f...

Страница 8: ...Power supply 230V AC Bobine coil 180V DC Bobine coil 180V DC 2 1 2 1 Bobine Coil Bobine Coil 2 1 Wiring diagram for Reduced response time option Built in power supply mandatory Frein brake 2 noir rou...

Страница 9: ...og the cover grille and the housing fins Lubricate the bearings of the motors fitted with grease nipples Cleaning Precautions to be taken before carrying out any cleaning operation check that the brak...

Страница 10: ...at least If the brake is not equipped with a release application indicator check the clearance periodically according to the rates and the energy to be dissipated on each braking operation see technic...

Страница 11: ...0034 9 2005 A1 2007 60034 14 2004 A1 2007 60079 0 2012 A11 2013 60079 31 2014 60529 1991 A1 2000 IEC 60034 5 2000 A1 2006 60034 6 1991 60034 7 1992 A1 2000 60034 9 2003 A1 2007 60034 14 2003 A1 2007 6...

Страница 12: ...Moteurs Leroy Somer Headquarter Boulevard Marcellin Leroy CS 10015 16915 ANGOUL ME Cedex 9 Limited company with capital of 65 800 512 RCS Angoul me 338 567 258 www leroy somer com...

Отзывы: