Parameter
Range
P1.01
Output Frequency
± Maximum Frequency Reference
(P2.02) Hz
P1.02
Output Voltage
0 to Maximum Output Voltage V
(110 V, 200 V Drive = 240 V, 400 V Drive = 480 V)
P1.03
Output Power
Drive Rating Dependent kW
P1.04
Motor RPM
±18000 rpm
P1.05
Drive State
Inhibited (0), Ready (1), NA (2), NA (3), Running (4), Supply Loss (5), Deceleration (6), Injecting DC (7),
NA (8), Error (9), NA (10), NA (11), NA (12), NA (13), NA (14), Under Voltage (15)
P1.06
Output Current
± Drive Rated Current x 2.2 A
P1.07
Torque Producing Current
± Drive Rated Current x 2.2 A
P1.08
Percentage Load
± Torque Current Maximum Limit %
P1.09
Alarm Indicators
00000000 to 11111111
P1.10
Drive Status Indicators
00000000 to 11111111
P1.11
Sequencer Input and Output Indicators
00000000 to 11111111
P1.12
Run & Direction Indicators
00000000 to 11111111
P1.13
Ramp Input
± Maximum Frequency Reference
(P2.02) Hz
P1.14
Ramp Output
± Maximum Frequency Reference
(P2.02) Hz
P1.15
T2 Analog Input 1 Percentage
±100.00 %
P1.16
T4 Analog Input 2 Percentage
±100.00 %
P1.17
T15 Frequency Input Percentage
±100.00 %
P1.18
Up/Down Percentage
0.0 to 100.0 %
P1.19
PID Output Percentage
±100.00 %
P1.20
PID Status Indicators
00000000 to 11111111
P1.21
PID Error
±100.00 %
P1.22
Motor Thermal Percentage
0 to 100 %
P1.23
Drive Thermal Percentage
0 to 100 %
P1.24
DC Bus Voltage
0 to Maximum D.C. Bus Voltage V
(110 V, 200 V Drive = 415 V, 400 V Drive = 830 V)
P1.25
Digital IO Indicators
00000000 to 11111111
P1.26
Parameter 1 Saved Value on Error
Dependent on parameter saved
P1.27
Parameter 2 Saved Value on Error
Dependent on parameter saved
P1.28
Parameter 3 Saved Value on Error
Dependent on parameter saved
P1.29
Error
0 to 255
P1.30
Error History 1
0 to 255
P1.31
Error History 2
0 to 255
P1.32
Error History 3
0 to 255
P1.33
Drive Diagnostic
0 to 17