HS45
2
Each HS45 has a two-phase output (A, B) 90° out of phase, with
complements (A, B), (A Quad B Output). A marker pulse with
complement (Z, Z) is also present.
The HS45 has a diagnostic package that includes Adaptive Electronics
and a Fault-Check output and red/green LED for local indication.
With this package, the HS45 can maintain itself, and provide an
alarm if there is a problem
before
the problem causes un scheduled
downtime.
ADAPTIVE ELECTRONICS
A perfect duty cycle consists of a waveform whose “high” and
“low” conditions are of the same duration (50%/50%). It is possible
over time for the duty cycle and edge separation to change due
to component drift, temperature changes, or mechanical wear.
The Adaptive Electronics extend the life of the HS45 by constantly
monitoring and correcting duty cycle and edge separation over time.
FAULT-CHECK
If the Adaptive Electronics reach their adjustment limit, the LED will
turn red and Fault-Check alarm will notify the drive and operator of
an impending failure. This output can occur before a failure, allowing
steps to be taken to replace the unit before it causes unscheduled
downtime. Fault-Check annunciation is available as an “alarm” output
through the connector.
SAFETY
The HS45 is not considered as a safety device and is not suitable for
connection into a safety system. The mechanical overspeed switch
(option 6xx) is suitable for connection into safety systems.
CAUTION
Do not disassemble mechanical overspeed option.
Doing so may modify the overspeed set point or cause
the switch to malfunction. If the factory seals are not
intact on the overspeed switch, do not use it--return to
the factory for service and calibration.
ELECTRICAL SPECIFICATIONS
A. Operating Power (Vin)
1. Volts ............................ 5-24 VDC in
2. Current ....................... 100mA, nominal, plus cable load
B. Output Format
1. 2O/ & Comp ................ A,A–, B,B– (differential line driver)
2. Marker: ....................... 1/Rev Z, Z–
C. Signal Type ..................... Incremental, Square Wave, 50 +/-10%
...................................
Duty Cycle.
D. Direction Sensing ........... O/ A leads O/ B for CW rotation as viewed
...................................
from the back of the tach
looking at the
...................................
non-drive end of
the motor.
E. Transition Sep. ............... 15% minimum
F. Frequency Range ........... See below
G. PPR ................................ 3-2,500***
H. Line Driver Specs: .......... See table
I. Connectors: .................... See connector options on page 1
MECHANICAL
A. Shaft Inertia .................... 1.59 lb-in-sec
2
B. Acceleration .................... 5000 RPM/Sec. Max.
C. Speed: ............................ 5000 RPM Max (also see overspeed)****
D. Weight: ........................... 10-12 lbs [4.5-5.5kg]
E. Vibration ......................... 20 Gs, 5-2000 Hz (any orientation)
F. Shock ............................. 100 Gs, any orientation
G. Shaft Engagement (clamp style)
5/8”-7/8” bore...................2” [51mm] min.
16-20mm bore..................51mm min.
1”- 1 1/8” bore..................1.75” [45mm] min.
25-30mm bore..................45mm min.
with overspeed switch......2.65” +/-0.05” [68mm +/-1.27mm]
****(Speed) Maximum RPM may be limited for PPR > 2,500 consult
factory with your application
ENVIRONMENTAL
Solid cast aluminum stator and rotor
Fully potted electronics, protected against oil and water spray
Operating Temperature:.......-40°C to +100°C.
(note for shaft codes C-F, S-Y, +85C or use option 500 = +100C)
MECHANICAL OVERSPEED SWITCH OPTION
A. Shaft Inertia .................... +0.0018 lb-in-sec
2
B. Acceleration .................... 3600 RPM/Sec. Max.
C. Speed: ............................ 1.25 x Overspeed set point Max.
Minimum trip speed: 700 RPM
Maximum trip: 3600 RPM
Ac/- 4% of trip point
Hysteresis: 40% of trip point
D. Weight:............................ +2.55 lbs [+1.16kg]
E. Vibration: ........................ 20 Gs, 5-2000 Hz (radial only)
F. Shock: ............................ 100Gs, any orientation
G. Electrical Contact (NO/NC Contact)
1. ................................... 6A/230VAC
2. .................................... 3A/380VAC
3. .....................................1A/125VDC
H. Operating Temperature:......-40°C to +100°C.
Frequency Range: @5V, @1m cable, 250 kHz Max
@24V, @300m cable, #8 output, 45 kHz Max
Max Cable Lenght: 300m
*** (PPR) Standard PPR is 5000. Consult factory with your application
for PPRs up to 25,000
A
B
Z
Timing Diagram (A leads B for CW rotation)
LINE DRIVER OPTIONS
Electrical Specifications
6
8
9
Units
Input Voltage
5-24
5-24
5-24
VDC
Nom Output Voltage
5-24
5-24
5
VDC
Line Driver
7272
HX
7272
Output Resistance Typ
13
75
13
ohms
Maximum Peak Current
1500
800
1500
mA
Maximum Average
Current
120
200
120
mA
Voh Typ
V
IN
-1
V
IN
-1
V
IN
-1
VDC
Vol Typ
0.5
0.4
0.5
VDC
Cable Drive Capacity
1000’ @ 5V
500’ @ 12V
200’ @ 24V
1000’
1000’
feet
Protection
Reverse
Voltage
yes
yes
yes
Short
Circuit
yes
yes
yes
Transient
yes
yes
yes
Mis-Wiring
yes
yes
yes
Alarm
+V(out)
Output voltage equal to input voltage.
Alarm*
Open collector, normally off, goes low on alarm,
sink 100mA max, 50VDC max
Marker
One per revolution. Pulse width
1/4 AB Period. Gated with A&B High
LED
Green = Power on
Red = Alarm
Orange = Line Driver Shutdown (Due