Nidec Avtron AV115 Скачать руководство пользователя страница 9

BLACK
RED

GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE

BROWN

VIOLET

OUTPUT

 

OPTIONS

9

4

5

10

2

8

3

7

6

1

Vcc

OUT

COM

300 OHM

MIN.

GND

FUNCTION

ENCODER

ØB

ØA
ØA

ØB

4-16 VDC SOLID STATE RELAY

Q5
MMFT6661

LINE

DRIVER

NOTE 1

CR8

{

FUNCTIONAL DIAGRAM

50 mA MAXIMUM

“W”

“P” & “Q”

MARKER
MARKER COMPLEMENT

COMMON
+V (Encoder Power)

{

BLACK
RED

GREEN
YELLOW

BLUE

GRAY
ORANGE
WHITE

BROWN

VIOLET

OUTPUT OPTIONS

9

4

5

10

2

8

3

7

6

1

MARKER
MARKER COMPLEMENT

GND

FUNCTION

+V (Encoder Power)

COMMON

24

VDC

RELAY

+

-

POWER

SUPPLY

115 VAC

SINK 100 mA MAXIMUM,
WITHSTAND 50 V MAXIMUM
REFERENCED TO COMMON

Q5
MMFT6661

ENCODER

FUNCTIONAL DIAGRAM

ØB

ØA
ØA

ØB

LINE

DRIVER

NOTE 1

CR8

“W”

“P” & “Q”

 

Applies to all model AV115 encoders, except for wiring option  “A”, “B”, “C”, “D”, “G”, “Q”, “R”, “S”, “T” and “U”.

 

ALARM OUTPUT CONNECTION

Avtron THIN-LINE II & III encoders provide an alarm signal if maintenance is required under specific circumstances. An 

optional internal alarm LED indicator is also available. Green indicates power on, red or orange indicates alarm on. Following 

are application examples provided to help install the alarm output. 
Example 1.   Alarm output using +V(OUT). +V(OUT) is equal to +V, the encoder power supply. 

THIN-LINE II™ & III™

Application Examples

Example 2.   Alarm Output Using Separate 24 VDC Power Supply and Relay. 

AV115 9

Содержание Avtron AV115

Страница 1: ...52mm DD 16mm DR 55mm D4 18mm DS 60mm DE 19mm MU 65mm DF 24mm MV 70mm DG 28mm MW 75mm DH 30mm MY 80mm DT 32mm MZ 85mm DJ 36mm E Extended Shaft Cover F Flat Cover T Flat Thru Hole Cover with Shaft Seal...

Страница 2: ...tor onto the shaft until it is in the proper position as shown in Figure 1 If a gauge is not available use the stator housing alignment grooves as show in Figure 3 STANDARD CAM SCREW ROTOR INSTALLATIO...

Страница 3: ...th NorthstarTM encoders with a cable shield connection on pin 10 Note that this option does not ground the shield Avtron still recommends grounding the shield at the drive end of the cable for all wir...

Страница 4: ...circuits the LED may take a few minutes to turn ORANGE To speed the troubleshooting process if possible spin the encoder while replacing individual output connections This will make the ORANGE LED con...

Страница 5: ...12 700 15 875 V RING WIDTH INSTALLED SHAFT DIAMETER COVER PLATE RETAINING RING V RING WIDTH SEE CHART FIGURE 4 4 M10 x 1 5 x 15 00 FULL THREAD 127 M A 150 00 0 75 MAX x 45 CHF B A 05 102 B A 4 M10 x...

Страница 6: ...TG 471967 1 375 1 3745 CH AVTR1 CH N A A36521 TH A36523 TH 471952 1 500 1 4995 CT AVTR1 CT N A A36521 TT A36523 TT 471969 1 625 1 6245 CJ AVTR1 CJ N A A36521 TJ A36523 TJ 471969 1 750 1 7495 CK AVTR1...

Страница 7: ...F N A A36522 MF A36524 MF 471964 28mm DG AVTR1 DG N A A36522 MG A36524 MG 471965 30mm DH AVTR1 DH N A A36522 MH A36524 MH 471966 32mm DT AVTR1 DT N A A36522 MT A36524 MT 471967 36mm DJ AVTR1 DJ N A A3...

Страница 8: ...TION Y OPTION L W OPTION G Q OPTION Y OPTION P Z OPTION L W OPTION G Q OPTION Y OPTION R S F D A H B J C K NC NC OPTION R S OPTION R S OPTION A B C D OPTION A B C D OPTION A B C D F D A H B I C J NC N...

Страница 9: ...0 V MAXIMUM REFERENCED TO COMMON Q5 MMFT6661 ENCODER FUNCTIONAL DIAGRAM B A A B LINE DRIVER NOTE 1 CR8 W P Q Applies to all model AV115 encoders except for wiring option A B C D G Q R S T and U ALARM...

Страница 10: ...BLE BORE SIZES SEE PAGE 1 P N TABLE 45 10 90 10 ROTOR 72 9 OPTION R MINI MS WITH PLUG OPTION S MINI MS WITH PLUG 4 STANDARD FLAT COVER SHOWN IN FRONT VIEW OPTIONAL THRU SHAFT COVER NOT SHOWN 3 DIMENSI...

Отзывы: