Page 40
Check the Air Gap Between the PMG Rotor and PMG
Stator:
1. Measure completely around the gap between the PMG rotor and
PMG stator with a feeler gauge.
2. Keep the gage at the tightest point, and turn the generator over to
measure the air gap as the rotor turns. Minimum air gap is 0.035
inch.
Check the Air Gap Between the Exciter Armature and
Exciter Stator:
1. Measure completely around the gap between the exciter armature
and exciter stator with a feeler gauge.
2. Keep the gage at the tightest point, and turn the generator over to
measure the air gap as the rotor turns. Minimum air gap is 0.035
inch.
Attach the exciter cover.
Connect the air temperature RTDs.
Mount the generator to the prime mover, and make the
electrical connections as described earlier.
Table 3 Exciter Air Gap
Exciter armature
diameter (inches)
Minimum air
gap (inches)
5 3/4
0.014
9 7/8
0.014
12 1/2
0.018
16 1/4
0.035
NOTE:
To measure air gap, measure
completely around the gap between the
exciter armature and the exciter field
with a feeler gauge. Keep the gauge at
the tightest point, and turn the generator
over to measure the air gap at the rotor
turns.
CAUTION:
Do not pry on the fan.
CAUTION:
Do not pound on the
rectifier.