Nidec 0478-0644-06 Скачать руководство пользователя страница 3

Commander S100 Step by Step Guide                                                                                                                            2

STEP 1:  Mount the drive

A drill template for wall mounting is included on the drive packaging for quick installation. No screws are required when 
mounting the drive onto a DIN rail.

Table 1-1 Drive dimensions

The drive should be operated in an ambient temperature range of -10 °C to 40 °C (14 °F to 104 °F). For temperatures 
exceeding this range output current deratings apply. For details on de-rating the drive and other environmental conditions 
follow the guidance in the Commander S100 User Guide. 

STEP 2:  Wire the drive 

Power connections

Connect the supply and motor connections using the cables and fuses or MCB's in Table 1-4. When using a single-phase 
supply, the supply should be connected to L1 and L2.

 

Always use a screened motor cable with the Commander S100 and connect this screen to the back-plate or the Cable 
Management Bracket accessory.

Frame 

size

Overall Dimensions (±0.5 mm)

Mounting Dimensions (±0.5 mm)

Weight

Ø

Mounting 

Hole 

Diameter

S100-01

156 mm

6.14 in

68 mm

2.70 in

130 mm

5.12 in

0.7 kg

1.54 lb

46 mm

1.81 in

145 mm

5.71 in

45 mm

1.77 in

22.5 mm

0.89 in

4.8 mm

0.19 in

S100-02

192 mm

7.56 in

68 mm

2.70 in

132 mm

5.20 in

0.8 kg

1.76 lb

46 mm

1.81 in

180 mm

7.11 in

45 mm

1.77 in

22.5 mm

0.89 in

4.8 mm

0.19 in

S100-03

192 mm

7.56 in

90 mm

3.54 in

132 mm

5.20 in

1 kg

2.2 lb

46 mm

1.81 in

180 mm

7.11 in

65 mm

2.56 in

37.5 mm

1.48 in

4.8 mm

0.19 in

Drive Clearances

S100-01x13, S100-01x23

All other drives

A

100 mm (3.94 in)

45 mm (1.77 in)

B

0 mm (0 in)

A

A

B

B

Power Terminals (S100 -034xx): 

5 mm (3/16 in) flat-blade screwdriver.

Power Terminals (all other models): 

3 mm (1/8 in) flat-blade screwdriver.

   Control Terminals (all models) :

3 mm (1/8 in) flat-blade screwdriver.

Drive Voltage 

Rating

100 V

200 V

400 V

Power 

Connection

0.5 Nm (4.4 lb in)

0.6 Nm 

(5.3 lb in)

Ground 

Connections

1.5 Nm (13.3 lb in)

Control 

Connections

0.4 Nm (3.5 lb in)

Figure 1-1 Power terminal connection

Table 1-2 Recommended Torque Settings

Содержание 0478-0644-06

Страница 1: ...ore using this product you must read and understand the safety information within the Commander S100 User Guide at www controltechniques com support Step By Step Guide COMMANDER S100 Part number 0478...

Страница 2: ...s access except by trained and authorised personnel 5 Electrical Hazards The voltages used in the drive can cause severe electrical shock and or burns and could be lethal Care is necessary when workin...

Страница 3: ...accessory Frame size Overall Dimensions 0 5 mm Mounting Dimensions 0 5 mm Weight Mounting Hole Diameter S100 01 156 mm 6 14 in 68 mm 2 70 in 130 mm 5 12 in 0 7 kg 1 54 lb 46 mm 1 81 in 145 mm 5 71 in...

Страница 4: ...ons The control connections shown above and the 485 port can be PELV rated when connected within a PELV circuit The terminals are not PELV rated if the relay is connected to a circuit exceeding Overvo...

Страница 5: ...3 8 6 6 6 15 1 5 1 5 24 24 S100 01223 1 6 0 25 0 33 3 2 3 4 6 6 15 1 5 1 5 24 24 S100 02S21 1 4 0 25 0 33 1 3 8 6 6 6 15 1 5 1 5 24 24 S100 01S33 2 4 0 37 0 5 1 4 7 6 6 6 15 1 5 1 5 22 22 S100 01233...

Страница 6: ...mander S100 User Guide Running and Speed Control Default Configuration Settings Run Always ensure it is safe to start the motor before doing so Provide an Enable signal to terminal 12 T12 Provide a ru...

Страница 7: ...is an error and to stop the drive running if enable run configuration is set appropriately UP DOWN Keys Used individually to increase or decrease editable values shown on the drive display UP DOWN Ke...

Страница 8: ...der as informa es de seguran a contidas no guia do utilizador que pode encontrar no URL abaixo Advarsel F r du tager dette produkt i brug skal du have l st og forst et sikkerhedsoplysningerne i bruger...

Страница 9: ...rsaliu adresu Twissija Qabel ma tu a dan il prodott inti g andek taqra u tifhem l istruzzjonijiet ta sikurezza fi dan il Gwida g all Utent fil URL t isfel Varning Innan du anv nder denna produkt m ste...

Страница 10: ...Company information Nidec Control Techniques Limited Registered Office The Gro Newtown Powys SY16 3BE Registered in England and Wales Company Reg No 01236886 0478 0644 06...

Отзывы: