![Nidec 0478-0644-06 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/nidec/0478-0644-06/0478-0644-06_step-by-step-manual_1687813003.webp)
Commander S100 Step by Step Guide 2
STEP 1: Mount the drive
A drill template for wall mounting is included on the drive packaging for quick installation. No screws are required when
mounting the drive onto a DIN rail.
Table 1-1 Drive dimensions
The drive should be operated in an ambient temperature range of -10 °C to 40 °C (14 °F to 104 °F). For temperatures
exceeding this range output current deratings apply. For details on de-rating the drive and other environmental conditions
follow the guidance in the Commander S100 User Guide.
STEP 2: Wire the drive
Power connections
Connect the supply and motor connections using the cables and fuses or MCB's in Table 1-4. When using a single-phase
supply, the supply should be connected to L1 and L2.
Always use a screened motor cable with the Commander S100 and connect this screen to the back-plate or the Cable
Management Bracket accessory.
Frame
size
Overall Dimensions (±0.5 mm)
Mounting Dimensions (±0.5 mm)
Weight
Ø
Mounting
Hole
Diameter
S100-01
156 mm
6.14 in
68 mm
2.70 in
130 mm
5.12 in
0.7 kg
1.54 lb
46 mm
1.81 in
145 mm
5.71 in
45 mm
1.77 in
22.5 mm
0.89 in
4.8 mm
0.19 in
S100-02
192 mm
7.56 in
68 mm
2.70 in
132 mm
5.20 in
0.8 kg
1.76 lb
46 mm
1.81 in
180 mm
7.11 in
45 mm
1.77 in
22.5 mm
0.89 in
4.8 mm
0.19 in
S100-03
192 mm
7.56 in
90 mm
3.54 in
132 mm
5.20 in
1 kg
2.2 lb
46 mm
1.81 in
180 mm
7.11 in
65 mm
2.56 in
37.5 mm
1.48 in
4.8 mm
0.19 in
Drive Clearances
S100-01x13, S100-01x23
All other drives
A
100 mm (3.94 in)
45 mm (1.77 in)
B
0 mm (0 in)
A
A
B
B
Power Terminals (S100 -034xx):
5 mm (3/16 in) flat-blade screwdriver.
Power Terminals (all other models):
3 mm (1/8 in) flat-blade screwdriver.
Control Terminals (all models) :
3 mm (1/8 in) flat-blade screwdriver.
Drive Voltage
Rating
100 V
200 V
400 V
Power
Connection
0.5 Nm (4.4 lb in)
0.6 Nm
(5.3 lb in)
Ground
Connections
1.5 Nm (13.3 lb in)
Control
Connections
0.4 Nm (3.5 lb in)
Figure 1-1 Power terminal connection
Table 1-2 Recommended Torque Settings