INSTALLATION INSTRUCTIONS 

the set Ambient  Light  Level. Set the Band Switch to OCC or AUTO 
mode. The Load will turn on only if motion is detected and the Ambient 

Light  Level also  below the set light level. 

Note: Use ambient light feature when daylight source is available. 

Back to factory default(daylight) 

Set the Band Switch to VAC,  press and hold the  Manual  ON/OFF 

Button for 6 seconds till the Load turns on, continue holding the button for 

another 5 seconds until the Load turns off, then release the button and 
set the Band switch to OCC or AUTO Mode, it confirms that the sensor 
switch goes back to factory default. 

+ OPERATION

The Sensor Switch can  be used  independently for any mode 
(AUTO, OCC, or VAC) as set by the Band Switch position under the 
control panel cover. Some might call the Vacancy mode, "Manual On 
Occupancy Mode." 

Manual On/Off Button 

By Pushing the Control  Panel  Cover,  the  Load  can be turned On/Off 

under either OCC or VAC mode (illustrated in Figure 5). 

Occupancy Mode - Auto on, Auto Off 

Load will be Automatically On once occupancy is detected. 

Vacancy Mode - Manual On, Auto Off 

On/Off Button must be pushed to turn On the Load. 

Automatic Off 

Under any Mode,  the sensor keeps the  Load  On until no motion is 

detected plus the set time delay. Turns Off automatically. 

Manual Off 

By pushing the Manual On/Off button, the Load can be turned Off under 
any Mode. Under AUTO/OCC Mode, the Load cannot be automatically 
turned On for 5 minutes after the last motion is detected. 

-04-

- . 

•  0 

Figure 5 

Auto Set Occupancy Mode 

Automatically set the time delay between 7 to 30 minutes based on occupancy 
patterns. Auto set behavior starts right after the time delay knob is 
turned away from Test Mode. Includes the walk-through mode. 

Walk-Through Mode 

In case of walk-through, the Load automatically turns On and then turns 

Off 2.5 minutes after a brief occupancy moment of 30 seconds. If 

motion is detected within the first 30 seconds and also continues in the 

coming 2.5 minutes,  Auto  Set Occupancy Mode applies. 

+ TROUBLESHOOTING

For proper operation, the Sensor Switch has to consume power from 

hot and 

Ground 

Therefore, a 

Secured Ground Wiring is required. 

Initialization 

The Sensor Switch needs to initialize for 3 munites. During the 

initialization the load might be turned On and Off several times. 

The Time Delay knob is set to 15 seconds by default, do not adjust it until 

initialization is completed and proper operation confirmed. 

The Load is out of control (frequently flashing) 

1. It can take up to three minutes for initial run.
2. Check the wiring connections, especially the Ground Wiring.

The Load does not turn On without LED flashing or LED flashes 

regardless of motion 

1.  Push Manual On/Off Button. If the load turns On, verify that the Sensitivity 

Range is on high. If the  Load  does not turn  On, go to Step 2.

2. Check the wiring connections. 

The Load does not turn On while LED flashes with motion detected 

1. Check to see if Ambient Light Level is enabled by covering the lens

by hand.

2. Push Manual On/Off Button If the load turns On, verify that Sensitivity 

Range is on high. If the Load does not turn On, go to Step 3

3.  Check the wiring connections, especially Hot Line and  Ground wiring. 

The Load does not turn Off 

1. There can be up to a 30 minute time delay after the last motion is

detected. To verify proper operation, turn the Time Delay Knob to 15s

(Test Mode) and make sure there is no motion (no LED flashing).

The Load should turn Off in 15 seconds.

-05-

2. Check if there is any significant heat source mounted within six feet (two

meters) that may cause false detection such as a high wattage light bulb, 
portable  heater, or HAVC device.

3. Check the wiring connections,  especially the Ground wiring to the
sensor switch.

The Load turns On when not desired 

1. Mask the Sensor Switch lens to eliminate unwanted coverage area. 

2. Turn the Sensitivity Level knob toward left to avoid false alert in

a small room and when near a doorway.

3. Set the Band Switch to the VAC positon.