Nicolaudie STICK-DE3 Скачать руководство пользователя страница 3

Sunlite Touch-sensitive Intelligent Control Keypad

Ref. STICK-DE3

Page 3/4

Technical datasheet

                         

Revision date   28 August 2012

              

www.nicolaudie.com

Version 1.0

2x10 pins EXTENSION connector

DMX CHIPS 

can be 

replaced here

         DMX 

     universe #1

         DMX 

      universe #2 

Ref:  SP485ECN-L

         MAX485 CSA

© Nicolaudie-Sunlite 1989-2012. All rights reserved.  We reserve the right without notice to amend the technical information and specifications.

RS232 triggering 

Make a cable using the 3 pins : TX, RX and G (GND) 

Set the RS232 parameters to : 9600bds  8 bits, no Parity, 2 Stop bits

- To play a scene, send 3 bytes :     

1    x    255

   

(x = scene number)

- To stop a scene, send 3 bytes :     

2    x    255

   

(x = scene number)

- To pause a scene, send 3 bytes : 

3    x    255

   

(x = scene number)

- To release a pause, send 3 bytes : 

4    x    255

   

(x = scene number)

- To reset a scene, send 3 bytes :     

5    x    255

   

(x = scene number)

Note: the scene number (x) can be from 1 to 40.  For instance, 11 means Page B Scene #3

Example of relay :  FINDER 
Ref. 22.23.9.012.4000

http://www.findernet.com/fr/products/

profiles.php?serie=22&lang=en

BLACKOUT  relay 

(energy saving) 

using the 2 pins : BK 

and G (GND)

PORTS triggering 

It is possible to start scenes using the input ports (contact closure). To activate a port, a brief 

contact must be established between the ports (1...8) and the ground (GND). This is a contact 

closure so there is no need to hold the connection, it acts like a basic switch. 

     P1   P2   P3  P4 ...                   GND