Nickel-Electro NE4-E Series Скачать руководство пользователя страница 12

FITTING ACCESSORIES FOR NE4 SERIES

GRP Gable Lids
Position the lid over the bath and lower into place.
The lids are designed to fit snugly so that condensate runs into the bath.

Stainless Steel Gable Lids
Position the lid over the bath and lower into place.
These lids have bo drip points, provide full working height across the bath when fitted and have a
ventilation gap.

Stainless Steel Flat Lids
Position the lid over the bath and lower into place.

Stainless Steel Raised Shelves
The raised shelf provides a reduced liquid depth for shallow vessels in NE4 series water baths.  With
recommended minimum water level in NE4 range of 70mm with this in place it will provide a working
depth of 5mm or 35mm.

Stainless Steel Test Tube Racks
Place the loaded test tube rack into the bath on top of either the stainless steel perforated shelf or the
raised shelf.

Thermometer Clip
This can be positioned anywhere on the perimeter of the bath by cliping over the edge. The thermom-
eter then lies flush with the top edge of the bath to prevent accidental damage.

Draining Syphon
Allows the easy and quick emptying of any water bath. Water temperature must be below 45°C before
emptying can commence.

Mounting Bracket
This Mounting Bracket is designed to fit the NE4 series Clifton Thermostirrers for mounting on any
number of vessels or tanks.
Maximum tank thickness for the Bracket = 30mm.Thumb wheel adjuster secures the Bracket and
Thermostirrer to tank.

Polypropylene Spheres
Place on top of the water/oil to provide a floating lid reducing evaporation and insulating the bath
reducing heat losses.

The Clifton Range - 3 Year Warranty

12

High Quality  Products at Affordable Prices

Содержание NE4-E Series

Страница 1: ...level float switch and if the liquid drops below the recommended level heating is automatically switched OFF top up liquid level then switch off and back on again using the mains switch located on th...

Страница 2: ...painted surfaces with Anti bacterial finish 8 Cleaning the stainless steel tank 8 Descaling the stainless steel tank 9 Decontaminationof Equipment 9 VirucidalDisinfectant 9 Disinfectant Sterilant 9 3...

Страница 3: ...olypropylene spheres when operating at temperatures above 60 C Take care when lifting the lid Steam and hot vapours can cause scalding 13 Always use the display or a thermometer to check the temperatu...

Страница 4: ...rs supplied Turn the thermostirrer upside down and screw the nylon propellor hand tight onto the spindle The spindle is threaded in the opposite direction to the propellor to ensure the propellor stay...

Страница 5: ...electrical supply Suitable Liquids Operating temperatures and recommended liquid options Ambient to 99 C Distilled water Heat transfer liquid The LB range is formulated for temperatures from 45 C to 9...

Страница 6: ...ater bath NE4 T series stainless steel tank with false base shelf fitted inside NE4 E series clear tank with shelf fitted Indicators heating temperature alarm timer and set temperature Tank View Low l...

Страница 7: ...to stabilise and take an actual reading at the far end of the bath to the Thermostirrer Where necessary adjust the temperature controller Heater indicator will illuminate Low Liquid Level Float Switc...

Страница 8: ...nge is maintained over its lifetime as the anti bacterial agent is integral within the paint In a laboratory environment it makes this one less source of contamination contributing to essential clean...

Страница 9: ...ment and instruments where autoclaving is neither practical nor necessary For more detailed information relat ing to how Virkon should be used with access to test reports www relyon dupont com Is Virk...

Страница 10: ...lifton prod ucts are easily recycled with majority of the product constructed from stainless or mild steels which can readily be re used or recycled In excess of 78 of this product range can be easily...

Страница 11: ...to suit 22 and 28 Litre Baths Stainless Steel Test Tube Racks Dimensions 270 x 70 x 138mm L x W x H 6870 Stainless Steel Test Tube Rack 26 Hole x 17mm Diameter 6871 Stainless Steel Test Tube Rack 16 H...

Страница 12: ...Place the loaded test tube rack into the bath on top of either the stainless steel perforated shelf or the raised shelf Thermometer Clip This can be positioned anywhere on the perimeter of the bath b...

Страница 13: ...Spares Service Diagram The Clifton Range 3 Year Warranty 13 High Quality Products at Affordable Prices...

Страница 14: ...t finish and is complete with a stainless steel shelf designed for good temperature stability STIRRED Features Include Sensitivity 0 2 C Uniformity 0 05 C Temperature range ambient 5 C 99 C Thermostat...

Страница 15: ...for electrical equipment for measurement control and laboratory use BS EN 61326 Electrical equipment for measurement control and laboratory use EMC requirements NICKEL ELECTRO LTD Manufacturers of lab...

Страница 16: ...BX0844 BX0845 www nickel electro co uk...