4 + 2 INPUTS BOARD CONNECTING TRADITIONAL DETECTORS TO SIL-BUS CONTROL PANEL 

 
 

Declaration of CE conformity: 

Nice s.p.a declares under its sole responsibility that the products described in this manual comply with the requirements set out by 

the Directives LVD 2014/35/EU - EMC 2014/30/EU. The complete declaration is available in our site  

www.silentron.it/dichiarazioni-ce/ 

Electronic alarm systems:

  IMQ Security Systems Certification body - Standard EN 50130-5; EN 50131-1; EN 50131-5-6; EN 50131-2-2; EN 50069-1; EN 60529; 

Certified Safety Level:  2; Environmental class II.  

 
Warnings and precaution: 

These devices can be used only in conjunction with our alarm system and in compliance with the instructions supplied in this manual. 

Devices can be played indoor or outdoor properly sheltered from the elements and according to operating temperature limits. This device must be installed and 
commissioned by qualified technical staff according to current regulations.  Any other use is considered improper and forbidden! The manufacturer is not liable for 
damages resulting from the improper use of the product other than those provided herein.

 

 

Operation: the device is a "concentrator " of alarms triggered by any kind of intrusion detector. It supplies the following inputs/functions: 
a) 2 NC/PULSE inputs. Select NC (see Figure) to control one or more Normally Closed magnetic contacts connected in series (500msec alarm delay upon contact 
opening).  Select PULSE to have each input control a NC/NO transition  phase pulse count roller shutters hardwired detector.   Alarm is triggered after 6 transition 
phases.  These inputs may not be used for EN 50131-3 standard  compliance since same are not balanced inputs. 
b ) 4 inputs for active detectors that control alarm and tamper functions over a balanced line. Connect the special resistors as described. Lockout signal (TC) is optional 
and positive when system is disarmed. 
c) The six types of alarm are individually managed by the control panel according to their configuration. 
 

Installation instructions: 

The unit is supplied in a casing to be flush-mounted in housing part no. 503. Its front cover is suitable  for an AVE plaque (accessory part no. 88329) or other types of 
plaques that have been suitably adapted by breaking their edges.  
50131-3 Standard: protection against opening and forced removal is achieved by ensuring that the tamper spring contact remains pressed against the bottom of the 
flush mount housing.  The device can also be surface mounted using accessory housing part no.  88328. Insert a screw into the wall whose head protrudes and presses 
against the tamper spring (rear tamper switch protection).   

Caution!

 If the device will not comply with EN 50131-1 and 3 standards if it is not installed with the above tamper protection. 

 

a) Remove the unit’s rear cover to open the device. 

 

b ) Set dip -switches according to application.  Exclude tamper (not compliant with standard 50131-3) and insert end of  line resistor if required. 
c) Temporarily connect the device to Touch-screen part no. 4020. Follow the audio and visual instructions on the display to address the device from the control panel, 
then disconnect it from the Touch-screen  You may clearly use all or only some of the available inputs. 
d ) Lay cables and mount unit as required.  
e) Ensure that bus line is not powered and connected it to the concentrator  following the supplied drawings. The unit is supplied with input and output terminals 
and to allow Bus cable to be cut and connected at both ends for installation ease.  
f ) Connect the 2 to 4 wire detector cables according to the kind of detector being used.  Non- insulated conductor sections must be fully contained within the 
terminals to prevent short circuits.  
g) Power the device once all Bus line connections have been completed. 
h) Close rear cover and fasten the unit. 
 

Programming, commissioning and operating instructions

: see manual of the employed Sil-Bus control panel. 

Technical Specifications: 

see drawings. 

 

LED indicators. 

BUS control LED diode:   

flashing = successful bus polling            

off = bus faults: check END R

 

and insert  or remove it as required. 

Protection Class:

 IP protection is stated by manufacturer and it is not certified. Declared protection is achieved when the device is flush mounted in 503 housing or 

surface mounted (88328 housing - 88329 cover).                 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Silentron Sil Bus 4080

Страница 1: ...s for installation and use IT Istruzioni ed avvertenze per l installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instal...

Страница 2: ...in a casing to be flush mounted in housing part no 503 Its front cover is suitable for an AVE plaque accessory part no 88329 or other types of plaques that have been suitably adapted by breaking thei...

Страница 3: ...apparecchio fornito in contenitore adatto per essere installato ad incasso in una scatola 503 La mascherina frontale pu sostenere una placca AVE accessorio cod 88329 oppure opportunamente adattata rom...

Страница 4: ...ant tre encastr e dans un bo tier 503 La fa ade peut supporter une plaque AVE accessoire code 88329 ou une fois opportun ment adapt e en cassant les bords pr d coup s des plaques d autres marques Norm...

Страница 5: ...rega en un contenedor id neo para su instalaci n empotrada en una caja 503 La m scara frontal puede sostener una placa AVE accesorio c d 88329 o convenientemente adaptada rompiendo los bordes predefin...

Страница 6: ...503 geeigneten Geh use geliefert Die vordere Maske kann eine AVE Plakette Zubeh r Art Nr 88329 tragen oder wenn sie durch Abbrechen der dazu vorgesehenen R nder adaptiert wird kann sie auch Plaketten...

Страница 7: ......

Страница 8: ...Nice SpA Oderzo TV Italia info niceforyou com www niceforyou com www silentron it IST4080A02MM_13 12 2019...

Отзывы: