12
3s
x3
x1
3s
Example of level one programming:
Example
activate the “Close after photo” function and deactivate “Opening delay”
1.
Enter level one programming by pressing P1 and P2 for at least 3 seconds
2.
Press P1 three times to move the flashing Led to the INPUT N°4 Led
(now it flashes quickly)
3.
Press 2 to activate the “Close after photo” function
(now the Led flashes slowly)
4.
Press P1 once to move the flashing Led to the INPUT N°5 Led
(now it flashes slowly)
5.
Deactivate the “opening delay” function by pressing P2
(now the Led flashes quickly)
6.
Press P1 and P2 for at least 3 seconds to exit the programming
mode and save modifications
4.2.3) Example of level one programming
These examples show how to activate or deactivate a level one
function, for example, how to activate the “Close after photo”
function and deactivate the leaf “Opening delay”.
3s
x3
3s
x4
3s
Example of level two programming:
Example
modifying “current sensitivity”
1.
Enter level one programming by pressing P1 and P2 for at least 3 seconds
2.
Press P1 three times until the flashing Led reaches the INPUT N°4 Led
3.
Press P2 for at least 3 seconds to shift to level 2
4.
Press P2 4 times until all the INPUT Leds are off (current sensitivity disabled)
5.
Press P1 to return to level one
6.
Press P1 and P2 for at least 3 seconds to exit the programming
mode and save modifications
4.2.4) Example of level two programming
This example shows how to modify a level two parameter, for
example, how to modify and disable current sensitivity.
P2
P1
P2
P1
P1
4
P1
5
P2
P2
P2
P2
P2
P1
P2
P1
P1
4
P1