![Nice MAESTRO200 Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/nice/maestro200-series/maestro200-series_instructions-and-warnings-for-installation-and-use_1686663046.webp)
20
– English
English
10.4.3 - “Remote” memorisation
You can store a new radio transmitter in the control unit, without pressing
its keys directly. A previously memorised and operational “OLD” trans-
mitter must be available. The “NEW” radio transmitter to be stored will
“inherit” the characteristics of the OLD one; that is, if the OLD radio trans-
mitter is memorised in mode 1, the NEW will be memorised in mode 1;
in this case, during the programming phase, any key can be pressed
on either of the two transmitters. If, on the other hand, the OLD radio
transmitter is memorised in Mode 2, you must press the key with the
command you want on the OLD transmitter, and on the NEW, the key to
which you want to associate that command.
Holding the two transmitters, position yourself within the operating range
of the automation and perform the following operations:
01.
Press the key on the NEW radio transmitter and hold it down for at
least 5s, then release it.
02.
Press the button on the OLD radio transmitter 3 times slowly.
03.
Press the key on the NEW radio transmitter once slowly.
At this point, the NEW radio transmitter will be recognised by the control
unit, and take on the characteristics that the OLD one had.
If there are other transmitters to memorise, repeat all the above steps for
each new transmitter.
10.4.4 - Deleting a radio transmitter
If you have available only one radio transmitter, use this operation to
delete it.
If the transmitter is memorised in Mode 1, one deletion phase is sufficient
and at point 3 you may press any key. If the transmitter is stored in mode
2, a deletion phase is required for each memorised key.
01.
Press the
P1
key (
fig. 36
) on the control unit and hold it down.
02.
Wait until the
led
P1
lights up, within three seconds.
03.
Press the key of the radio transmitter to be deleted for at least three
seconds. If cancellation was successful the
led
P1
will flash quick-
ly five times. If
led
P1
emits 1 slow flash, the deletion phase was
unsuccessful because the transmitter is not memorised.
04.
If there are other transmitters to delete, keeping
P1
depressed,
repeat step 3 within another 10 seconds; otherwise, the deletion
phase will stop automatically.
10.4.5 - Deleting all memorised radio transmitters
This operation deletes all memorised transmitters.
01.
Press the
P1
key (
fig. 36
) on the control unit and hold it down.
02.
Wait for the
P1
led
to light up, then wait for it to switch off and then
wait for it to flash 3 times.
3
Release button
P1
exactly during the third flash.
4
Wait for around 4s for the deletion phase to finish; during this time the
P1
led
will flash very quickly.
If the procedure is successful, after a few moments the
P1 led
will flash
slowly 5 times.
10.4.6 - Digital selector switch DS100 programming and deletion
Mode 1 memorisation – with this memorisation, the commands that can
be sent by pressing the
A
,
B
or
C
buttons on the DS100 selector switch
are:
- key
A
- “Step by Step” command,
- key
B
- “Pedestrian Opening” command,
- key
C
- “Open Only”.
To memorise DS100:
01.
Press
P1
(
fig. 36
) for at least 3 s. When the
P1 led
lights up, release
the key.
02.
Within 10 s, type in the factory combination 11 (or the secret combi-
nation, if the factory combination has been changed), and press any
of the keys A, B or C on the DS100 selector switch for at least 3 s.
If the procedure was memorised correctly, the
P1
led
will flash 3
times.
03.
If there are other selector switches to memorise, repeat step 2 within
another 10 seconds; otherwise, the memorisation will stop automati-
cally.
Mode 2 memorisation – with this memorisation, the commands that can
be sent by pressing the
A
,
B
or
C
buttons on the DS100 selector switch
are those listed in
table 9
.
In Mode 2 each key requires its own memorisation phase.
To memorise DS100:
01.
Press
P1
(
fig. 36
) on the control unit, the same number of times as
your desired command, according to
Table 14
(e.g. 3 times for the
“Open Only” command).
02.
Check that
P1
led
emits a number of quick flashes which are equal
to the selected command.
03.
Within 10 s, type in the factory combination 11 (or the secret combi-
nation, if the factory combination has been changed), and press the
P1
LP1
LP2
LP3
P2
P3
36
led P1
led P2
led P3
TABLE 9
1 time
“Step-by-Step” command
Commands the automation as described in table 3 (Step-by-Step function)
2 times
“Pedestrian opening” command
Causes partial opening of one or two leaves as described in table 3 (Pedestrian Opening)
3 times
“Open only” command
Causes the leaves to open (open - stop - open etc.)
4 times
“Close only” command
Causes the leaves to close (close - stop - close etc.)
5 times
“Stop” command
Halts the manoeuvre
6 times
“Apartment block Step-by-Step”
command
The command has no effect on opening, when closing the command causes the move-
ment to reverse, that is, opens the leaves
7 times
“High priority Step-by-Step” command
Works also when the automation is locked
8 times
“Pedestrian opening 2” command
Causes partial opening of leaf M2, equal to halfway
9 times
“Pedestrian opening 3” command
Causes partial opening of both the leaves, equal to halfway
10 times “Open + lock automation” command
Causes an opening manoeuvre and when this is complete, the automation is locked;
the control unit will not accept any command other than “High priority Step-by-Step” and
“Release” of the automation
11 times “Close + lock automation” command
Causes a closure manoeuvre and when this is complete, the automation is locked; the con-
trol unit will not accept any command other than “High priority Step-by-Step” and “Release”
of the automation
12 times “Lock automation” command
Causes a halt of the manoeuvre and locks the automation; the control unit will not accept
any command other than “High priority Step-by-Step” and “Release” of the automation
13 times Release automation” command
Causes automation release and reset to normal operation
Содержание MAESTRO200 Series
Страница 2: ......
Страница 9: ...Français 7 Français E B A 6 Distance E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Страница 10: ...8 Français Français OK b c d a Maximum 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Страница 33: ...English 7 English E B A 6 Distance E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Страница 34: ...8 English English OK b c d a Maximum 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Страница 57: ...Italiano 7 Italiano E B A 6 Distanza E minimo 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Страница 58: ...8 Italiano Italiano OK b c d a Massimo 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Страница 81: ...Polski 7 Polski E B A 6 Odległość E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Страница 82: ...8 Polski Polski OK b c d a Maksymalny 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Страница 111: ......