Installation of the Input and Relay Module K30 - SETTING

Installation of the Input and Relay Module K30

Insert the plug of the module connection cable in the J2 slot on the main 
board of the D-PRO Automatic. Insert the module board onto the four black 
guide bolts on the main board. Fasten the module by bolting the four supplied 
spacers onto the guide bolts.

Relay functions

 

Relay 1  -->  external traf

fi

 c lights (red / green)

 

Relay 2  -->  internal traf

fi

 c lights (red / green)

 Relay 

--> 

traf

fi

 c lights On/Off

 

Relay 4  -->  potential-free 1 up (display of upper 

fi

 nal position)

 

Relay 5  -->  potential-free 2 down (display of lower 

fi

 nal position)

 

Relay 6  -->  photoelectric barrier test 1

 

Relay 7  -->  photoelectric barrier test 2

Settings on the cover board with the parameters P120 to P133!

Testing of the photoelectric barriers - see Fig. 2

Only photoelectric barriers with a transmitter/receiver compliant with the standards 
can be used as an anti-entrapment photoelectric barrier.
The transmitter or, if two anti-entrapment photoelectric barriers (internal and 
external) are used, both transmitters are to be connected to the terminals O10 
and O11 or O12 and O13 on the Input and Relay Module K30.
The receiver contact then directly intervenes in the safety circuit (during the 
upward movement). The connection is made on the main board of the D-PRO 
Automatic Door Control at terminal X6/J33.

ATTENTION

: Operation of the anti-entrapment safety devices is automatically 

tested before each ascent. The parameters P132 and P133 must therefore be 
set to 1.

Automatic closing ON/OFF

If a switch is connected to the terminals I5 and I6, it can be used to enable or 
disable the “automatic closing” function.
To switch off automatic closing, the contact must be opened.

External OPENING using buttons

If traf

fi

 c lights for two-way traf

fi

 c are connected to the Input and Relay Module 

K30, a button contact with zero potential (closing contact) must be connected 
to terminals I9 and I10 to activate the external green traf

fi

 c light.

Partial opening with electronic limit switch

If the D-PRO Automatic control unit operates with an electronic limit switch 
(EES), a selector switch for activation of the partial opening must be connected 
to terminals I7 and I8.

Connection of a 

fi

 re alarm system

The potential-free contact of a 

fi

 re alarm system can be connected to the 

terminals I1 and I2. The functions that are then available can be set through 
parameter P125.

Function light barrier 2

The potential-free contact of a second function light barrier can be connected 
to the terminals I11 and I12.

ATTENTION

: All inputs and outputs of the Input and Relay Module K30 can be 

assigned functions other than those stated here. The reprogramming is done 
through parameter entries on the cover board (see parameters P120 through 
P133 in the parameter list).

6
7
8
9

10
11
12
13

1
2
3
4
5

8
7
6
5
4
3
2
1

12
11
10

9

1

Traffi c light

L1

Red external

Green external

Green internal

Red internal

Ox

Ox

Ix

LED (green)

mains voltage

LED (yellow) 

automatic closing 

On/Off

LED (red)

Photoelectric barrier 

test

Display of upper fi nal position

Display of lower fi nal position

Test of anti-entrapment
photoelectric barrier 1

Test of anti-entrapment
photoelectric barrier 2

Function light barrier 2
(must be bridged)

UP external

Half opening height

Automatic closing enabled
(must be bridged)

Dead-man operation
(must be bridged)

Fire alarm Close Door
(must be bridged)

2

 – English

EN

Содержание M01 Series

Страница 1: ...installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalación y el uso PL Instrukcje i ostrzeżenia do instalacji i użytkowania NL Aanwijzingen en aanbevelingen voor installatie en gebruik Input and Relay Module K30 Industrial D Pro Automatic ...

Страница 2: ... the system during installation The packaging material of the door control must be disposed of in strict observance of local regulations ATTENTION Store this manual carefully to facilitate future disposal and maintenance work on the equipment KNOWLEDGE OF THE SYSTEM AND PREPARATION FOR INSTALLATION Description and use The Input and Relay Module K30 is an extension for the D PRO Automatic Door Cont...

Страница 3: ...n be used to enable or disable the automatic closing function To switch off automatic closing the contact must be opened External OPENING using buttons If traffic lights for two way traffic are connected to the Input and Relay Module K30 a button contact with zero potential closing contact must be connected to terminals I9 and I10 to activate the external green traffic light Partial opening with e...

Страница 4: ...lity that the product identified above complies with the provisions of the following directives 2006 42 EC DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 machinery directive The following harmonized standard was applied EN ISO 13849 2008 The safety functions Monitoring of external safety elements contact x6 Cat 2 PLd end position monitoring Cat2 PLd safety circuit emergency stop C...

Страница 5: ...I nostri azionamenti e centrali di comando sono omologati dal TÜV NORD XXXXX_17 09 2015 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...

Отзывы: