5 - OUTPUTS AND LED INDICATORS

5.1 -  Operating principle of the relays

The factory setting establishes that both relays function according to the principle of standby current. The 

operation principle of the relay can be set according to the following table by using jumpers, if fitted on the 

card. In this regard, the housing of the detector must be opened carefully (see table 7).

  - Warning! On the card there are components which are sensitive to static energy. When 

working with the device open, appropriate precautions are required. Do not touch the compo-

nents or conductors! The warranty will be nullified for damages caused by improper handling!

Re

la

is

JP

1

JP

2

3

2

1

JP

3

JP

4

Platine

3

2

1

3

2

1

3

2

1

Table 7

Detector status

Relay operating principle

1*)

2

3

4

Tension is off
Free loop
Output
Loop fault

) Factory setting

Relay

Jumper

Position

Relay function

1

JP1

1-2

Normally open contact

2-3

• 

Normally closed contact

JP3

1-2

• 

Working current principle

2-3

• 

• 

Quiescent current principle

2

JP2

1-2

• 

Normally open contact

2-3

Normally closed contact

JP4

1-2

Working current principle

2-3

Quiescent current principle

5.2 - LED indicators

The green LED indicates that the detector is ready for operation. The red LED, depending on the occupa-

tion status of the loop, indicates the activation of the relay output (see table 8).

Table 8

Green LED loop control

Red LED loop status

Detector status

Off

Off 

No power voltage

Flashing light

Off

Frequency indication or adjustment

On

Off

The detector is ready, free loop

On

On

The detector is ready, occupied loop

Off

On

Loop fault

5.3 -  Loop frequency indication

About 1 s after the adjustment of the detector, the loop frequency is indicated by flashing signals on the 

green LED. First of all, the 10 kHz location of the frequency value will be displayed. For each frequency 

value of 10 kHz, the green LED of the detector channel will flash once. After 1 sec. the 1 kHz position will 

be displayed in the same manner. If the value at the position of 1 kHz is ‘0’ the LED will flash 10 times. 

The 1 kHz position flashes are slightly shorter than the 10 kHz position flashes. 
Example of 57 kHz loop frequency:

             Tens

                    Units

1 s

             5x 10 kHz

                7x 1 kHz

6 - ELECTRICAL CONNECTIONS

 - Warning! 

– Incorrect connections can cause faults or hazards; therefore ensure that the specified con-

nections are strictly observed and performed by experienced and qualified personnel. 

– Hook up the unit with the electrical power shut off. 

Table 9

Description

Connection

Power input

0 V

24 V

Relay 1

1a

1b

Relay 2

2a

2b

Loop 1 and Loop 2

Connector block with 4 - poles

Installation examples

Roadway

2m

1m

1

Roadway

0,8m

0,8m

2m

2m

2

Roadway

Gate

1m

1m

1m

>1m

3

Roadway

B

A

C

D

4

5-8 mm

A

B

D

C

30

-5

0m

m

5

Fig. 1 - 

Recommended for cars, 

lorries, buses

Fig. 2 - 

Recommended for motor-

bikes and bicycles

Fig. 3 - 

Applications requiring low 

sensitivity at the side 

Fig. 4 - (A) 

Floor

 

(B) 

Twisted wire

 

(C) 

Groove

 

(D) 

Loops

 

Fig. 5 - (A) 

Sealant

 

(B) 

Groove

 

(C) 

Twine

 

(D) 

Loops

7 - DISPOSAL OF THE PRODUCT

This product constitutes an integral part of the automation system, therefore it must be dis-

posed of together with it. 

As in installation, also at the end of product lifetime, the disassembly and 

scrapping operations must be performed by qualified personnel. This product is made up of different types 

of material, some of which can be recycled while others must be disposed of. Seek information on the 

recycling and disposal systems envisaged by the local regulations in your area for this product category. 

 

– Some parts of the product may contain polluting or hazardous substances which, if disposed 

of into the environment, constitute serious environmental and health risks.

As indicated by the symbol, the product may not be disposed of as domestic waste. Sort the 

materials for disposal, according to the methods envisaged by current legislation in your area, 

or return the product to the retailer when purchasing an equivalent product. 

 - Local legisla-

tion may include the application of serious fines in the event of improper disposal of 

this product.

8 - TECHNICAL SPECIFICATIONS

Note

: • All technical specifications stated herein refer to an ambient temperature of 20° C (± 5° C). • Nice S.p.A. 

reserves the right to apply modifications to products at any time when deemed necessary, maintaining the same 
intended use and functionality.

• 

Dimensions:

 79 x 22.5 x 90 mm (H x W x L without plug) • 

Protection type:

 IP40 

• Power supply: 

24 

V   /   ±10 % max. 2.0 W • 

Operation temperature:

 -20°C to +70°C • 

Air humidity:

 max 95% with 

no condensation • 

Loop inductivity:

 25-800 μH, recommended 100-300 uH • 

Frequency range:

 30-

130 kHz in 2 steps • 

Sensitivity:

 from 0.01% to 0.64 % (Δf/f) in 4 levels - from 0.02% to 1.3% (ΔL/L) • 

Delay:

 5 min or uninterrupted • 

Electric power line of the loop:

 max. 250 m • 

Loop resistance:

 max. 

20 Ohm (including power line) • 

Relay:

 250 mA / 24 V   /   (min.1 mA/5 V) • 

Energise delay:

 normally 

100 ms • 

Signal duration:

 > 200 ms • 

De-energise delay:

 normally 50 ms • 

Connection:

 Screw ter-

minals (power supply, relay) – Snap-on terminal clamps (loops connection) 