EN
3
03.
Check the coverage of the protected area: make short movements inside the area and
check the signals emitted by LED
L1
(
fig. 2
). Adjust the sensitivity value if necessary.
04.
After adjusting the sensitivity, to reduce the risk of improper alarms, set
dip-switch 3
to ON
(2 pulses per alarm).
05.
After the operation check, it is advisable to set
dip-switch 4 to ON
to turn off the
signalling of LED
L1
(
Fig. 2
) and be compliant with standard 50131.
06.
Turn
dip-switch 5 ON
to activate the anti-blinding function.
Caution!
- The use of the Anti-blinding function excludes compliance with standard
EN50131.
07.
If an extremely hot environment requires it,
turn dip-switch 6 ON
to activate the auto-
matic temperature compensation.
08.
Close
jumper JP1
(
fig. 2
) to activate the double alarm function and acquire the sensor
in AND on itself.
Table 1
- Dip-switch programming
Switch Status
Function
1-2
OFF OFF
Infrared sensor sensitive area up to 6 m (fig.
7
)
ON
OFF
Infrared sensor sensitive area up to 8 m (fig.
7
)
OFF
ON
Infrared sensor sensitive area up to 10 m (fig.
7
)
ON
ON
Infrared sensor sensitive area up to 12 m (fig.
7
)
3
OFF
No. of infrared pulses per alarm = 1 (fig.
10 A
)
ON
No. of infrared pulses per alarm = 2 (fig.
10 B
)
4
OFF
Signalling LED active
ON
Signalling LED off
5
OFF
Anti-blinding function disarmed
ON
Anti-blinding function armed
6
OFF
Temperature compensation off
ON
Temperature compensation on
Содержание HSDIM23
Страница 2: ......
Страница 53: ...4 A B 5...
Страница 54: ...6 7 A B...
Страница 55: ...7 8 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 5 4 3 2 1...
Страница 56: ...10 A B...
Страница 57: ...11...
Страница 58: ......
Страница 59: ......
Страница 60: ...IS0179A02MM_26 11 2015 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...