––– GROUP “B” PROCEDURES ––
Procedures run with the motor head buttons
B.1 - Precise adjustment of the UP (“0”) and DOWN (“1”) limit switch positions
NOTES AND WARNINGS
• This adjustment can be done at any time, on condition that the limit switch positions have already been programmed.
• The following procedure describes the setting of the Upper limit switch “0”.
To adjust the Lower limit switch “1”: (in step 1)
command a DOWN movement
(rather than UP);
(in step 2)
adjust the height of limit switch “1” (instead of the height of limit switch “0”);
(in step 3)
as in the figure below.
1
2
3
Command
an UP
movement
(x
1
)
“
0
”
Adjust the po-
sition of limit
switch “0”.
“
0
”
Press and release the key.
Wait for the move-
ment to finish at posi-
tion “0”.
Press the buttons until you reach the desired position.
Note
– Each step of the motor corresponds to a rotation
of around 2°.
3
end
=
5
sec
3
Hold down either of the two buttons;
release it after
5 seconds
;
count 3 movements.
B
B.2 - Procedure for adding or deleting a command assignment (mapping)
1
2
=
5
sec
=
5
min.
On the motor head:
hold down both
buttons and
release them after
5 seconds
;
observe the
movements for
5 minutes.
2
3
end
=
5
sec
Note: As you are completing
the procedure, press and re-
lease the button 3 times to
delete the T4 BUS address.
x
3
To exit:
hold down both buttons and
release them after
5 seconds
.
B
––– GROUP “C” PROCEDURES ––
only available using a specific programmer (e.g.: TTP)
NOTES AND WARNINGS
•
To run the procedures in this group, you must use a compatible programmer (see the “Nice Screen” catalogue, also available on www.niceforyou.com).
•
For the programming and adjustment procedures possible with a given programmer, see the programmer’s user manual and interface.
C