background image

1

Circuit board

2

Supply terminal block

2.1

Phase 230 V~.

2.2

Neutral.

3

Input terminal block channel 1.

3.1

Screen connection.

3.2

Temperature sensor connection.

3.3

Temperature sensor connection.

4

Input terminal block channel 2.

4.1

Screen connection.

4.2

Temperature sensor connection.

4.3

Temperature sensor connection.

5

Input terminal block channel 3.

5.1

Screen connection.

5.2

Temperature sensor connection.

5.3

Temperature sensor connection.

6

Input terminal block channel 4.

6.1

Screen connection.

6.2

Temperature sensor connection.

6.3

Temperature sensor connection.

7

Output terminal block 1.

7.1

Screen connection.

7.2

Signal ground connection.

7.3

Mirroring of input channel 1.

7.4

Mirroring of input channel 2.

7.5

Mirroring of input channel 3.

7.6

Mirroring of input channel 4.

8

Output terminal block 2.

8.1

Screen connection.

8.2

Signal ground connection.

8.3

Mirroring of input channel 1.

8.4

Mirroring of input channel 2.

8.5

Mirroring of input channel 3.

8.6

Mirroring of input channel 4.

9

Output terminal block 3.

9.1

Screen connection.

9.2

Signal ground connection.

9.3

Mirroring of input channel 1.

9.4

Mirroring of input channel 2.

9.5

Mirroring of input channel 3.

9.6

Mirroring of input channel 4.

10

Output terminal block 4.

10.1

Screen connection.

10.2

Signal ground connection.

10.3

Mirroring of input channel 1.

10.4

Mirroring of input channel 2.

10.5

Mirroring of input channel 3.

10.6

Mirroring of input channel 4.

R

TSF 10

Component placement

List of components

3

4

5

6

10

9

8

7

2

1

1
2
3
4
5

6

1
2
3
4
5

6

1
2
3
4
5

6

1
2
3
4
5

6

1

2

1
2
3

1
2
3

1
2
3

1
2
3

FIGHTER 1310   VP1

VP4 alt en andra TSF 10

21

13b

30

6 5 4 3 2 1

1 2 3 4 5 6

6

7

8

5 4 3 2 1

Kanal 1In

Utetemperatur

Kanal 3In

Värmebärare fram

Kanal 4In

Värmebärare retur

FIGHTER 1310   VP2

21

30

6 5 4 3 2 1

6

7

8

5 4 3 2 1

FIGHTER 1310   VP3

21

30

6 5 4 3 2 1

6

7

8

5 4 3 2 1

Kanal 2In

Reservingång

UG

UG

FG

RG

FG
RG

UG

FG

RG

NIBE AB

SWEDEN

Box 14
Järnvägsgatan 40
SE-285 21  MARKARYD

Tel: +46 - (0)433 - 73 000
Fax: +46 - (0)433 - 73 190
www.nibe.com

Outdoor temperature

Channel 1

Channel 3

Channel 2

Channel 4

Heating medium flow

Spare connection

Heating medium return

HP4 or another TFS 10

HP3 

HP2 

HP1 

UG  Outdoor temperatur 
FG  Heating medium flow, WW-out
RG  Heating medium return, WW-in