background image

TSF 10 is connected to 230 V/AC supply voltage.
Recommended cable cross section: 0.5 – 0.75 mm

2

.

The supply can be taken from terminal block (13b) in
FIGHTER 1310. All signal cables should be screened.
The screen is connected to the terminal block on the
circuit bord in TSF 10 and to the chassis on the heat
pump. Screened signal cable, type LiYCY, is recom-
mended. Channel 1 is intended for outdoor tempera-
ture. Channels 3 and 4 are intended for the heating
medium flow and heating medium return. 

TSF 10 is a temperature signal distributor, to which it
is possible to connect a set of temperature sensors
(outside sensor, flow sensor and the like) to two, three
or four geothermal heat pumps of the type FIGHTER
1310. Each temperature signal distributor has four
inputs (channels) for temperature sensors and in turn
each input has four outputs.

MAV GB 0337-2 

611773 

TSF 10

R

R

INSTALLATION INSTRUCTIONS

TSF 10

The inputs on TSF 10 are copies of the input stages
on the CPU-board in FIGHTER 1310 and the outputs
are copies of the temperature sensors supplied with
FIGHTER 1310. The signal ground is internally
strapped in FIGHTER 1310, which means a common
signal ground conductor can be used between TSF 10
and the heat pump. If more than four FIGHTER 1310
are to be to operated simultaneously use two (or
more) TSF 10. You then allow one output to become
the input the  next temperature signal distributor. In
doing so you never need more than one temperature
sensor per measurement point irrespective of the
number of heat pumps.

General

TSF 10

LEK

Svart

Vit

Grå

Brun

Röd

Röd

Grå

Grå

1

R

0

+2

-2

max

min

13b

21

30

Electrical connection

Function

Отзывы: