Program settings
MENU SETTINGS
MENU 1.1.1, 1.1.2 - HEATING AND COOLING
Set the temperature (with room sensor installed
and activated):
Heating
Setting range: 5 – 30 °C
Cooling (accessory required)
Setting range: 5 – 35°C
The value in the display appears as a temperature in °C,
if the zone is controlled by a room sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
MENU 1.1.3 - HUMIDITY
Setting range: 30 – 90%
This menu is shown if the accessory is installed and has
been activated in menu 7.1.6.4 - "Limit humidity in heat".
Here, you set the desired value for relative humidity
(RH).
MENU 1.3 - ROOM SENSOR SETTINGS
Here, you make your settings for room sensors and
zones. The room sensors are grouped by zone.
MENU 1.3.3 - ROOM SENSOR SETTINGS
Name room sensor
Enter a name for the relevant room sensor.
Control room sensor
Setting range: on/off
Here, you select the zone to which a sensor will belong.
It is possible to connect multiple room sensors to each
zone. Each room sensor can be given a unique name.
The control of heating, cooling, humidity and ventilation
are activated by ticking each option. Which options are
shown depends on which type of sensor is installed. If
control is not activated, the sensor will be the displaying
sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
MENU 1.3.4 - ZONES
Here, you add and name zones. You also select the cli-
mate system to which a zone is to belong.
MENU 5.4 – WIRELESS DEVICES
In this menu you connect wireless units, and manage
settings for connected units.
Add the wireless unit by pressing "add unit". For the
quickest identification of wireless unit, it is recommen-
ded that you put your master unit in search mode first.
Then put the wireless unit in identification mode.
A zone is created automatically when you connect a
new wireless room sensor. (Default setting: One zone
per climate system.)
When you decide to create additional zones, you select
a name as well as the climate system to which the zone
will belong.
MENU 5.4.1 – INDOOR SENSORS THS 10
Name unit
Enter a name for the relevant indoor sensor.
Zone
Setting range: zone 1 - n
Delete unit
Setting range: yes/no
Name unit:
Here, you name THS 10.
Zone:
Here, you can change the zone to which THS 10
will belong.
Remove unit:
Here, you can choose to remove the unit.
MENU 7.1.4.4 - DEMAND-CONTROLLED
VENTILATION
Humidity controlled ventilation
Alternative: on/off
Highest fan speed
Setting range: 1 – 100%
Lowest fan speed
Setting range: 1 – 100%
Time interv. change of fan speed
Setting range: 1 – 60 minutes
Controlling zones
Activate zones for demand-controlled ventilation.
THS 10 | GB
16
Содержание THS 10
Страница 2: ......
Страница 10: ...Tekniska data THS 10 067725 Art nr 51x86x26 mm Mått BxHxD THS 10 SE 10 ...
Страница 18: ...Technical specifications THS 10 067725 Part No 51x86x26 mm Dimensions WxHxD THS 10 GB 18 ...
Страница 26: ...Technische Daten THS 10 067725 Art nr 51x86x26 mm Abmessungen BxHxT THS 10 DE 26 ...
Страница 34: ...Tekniset tiedot THS 10 067725 Tuotenumero 51x86x26 mm Mitat LxKxS THS 10 FI 34 ...