Installing the sensor
Sensor, hot water charging WP5-BT6, hot water top
(WP5-BT7) and solar coil WP5-BT54 are therefore
placed in the designated submerged tube in AHPS, see
image below. Secure the sensor cables with enclosed
plastic clips.
BT6
BT54
BT7
Temperature sensor, solar panel (WP5-BT53) is installed
with heat conducting paste and secured with cable
ties.
Place the sensor in solar panel's submerged tube by
the outlet from the solar panel.
BT53
Use cable type LiYY, EKKX or similar.
Caution
Cable splicing for the solar panel must fulfil
IP54.