Nibe S2125 Скачать руководство пользователя страница 1

NIBE S2125 is an intelligent, inverter-controlled
air/water pump. With NIBE indoor modules, it forms
a very efficient climate system for your home. NIBE
S2125 provides optimised savings as it automatically
adapts to your home’s output requirements all year
around.

The NIBE S2125 has an optimised seasonal perform-
ance factor*, which results in low operating costs
and high-performance hot water. The working area
gives a supply temperature of up to 75°C. At an
outdoor temperature down towards –25°C, it still
delivers up to 65°C, while the noise level stays low.
Available in two power sizes, 8 and 12.

Together with the NIBE S-series indoor module with
built-in wifi connection and the possibility of wireless
accessories, the S-series is a natural part of your
connected home. Smart technology adjusts the in-
door climate automatically while you’re in complete
control from your phone or tablet. Giving high com-
fort and low energy consumption, while doing nature
a favour at the same time.

• Optimised seasonal performance factor* and low

operating costs.

• Working range up to 75°C supply temperature and

65°C at an outdoor temperature of –25°C.

• New design for low noise level.

*The NIBE S2125 has a rating of SCOP of 5.0 (Average climate,
35/55 °C) and SCOP of >4.1 (Cold climate, 35/55 °C) in accordance
with European standard EN 14825:2018, i.e. the standard for de-
termining the reference seasonal effect level, SCOP. Applies to
S2125 -8 and -12.

IT'S IN OUR NATURE

NIBE.EU

Air/water heat pump
NIBE S2125

Содержание S2125

Страница 1: ...le with built in wifi connection and the possibility of wireless accessories the S series is a natural part of your connected home Smart technology adjusts the in door climate automatically while you re in complete control from your phone or tablet Giving high com fort and low energy consumption while doing nature a favour at the same time Optimised seasonal performance factor and low operating co...

Страница 2: ...modules are complete with a smart and user friendly control system hot water heater additional heat self regulating circulation pump etc The control modules SMO offer a flexible system solution that can be easily customised For systems with SMO different components such as water heaters additional heat and other accessories can be selected to suit the installation s requirements There is a wide ra...

Страница 3: ...COMPATIBLE INDOOR MODULES VVM AND CONTROL MODULES SMO SMO S40 VVM S320 X X S2125 8 X X S2125 12 NIBE S2125 3 IT S IN OUR NATURE ...

Страница 4: ...steel 3x230 V Part no 069 201 VVM S320 Stainless steel 1x230 V Part no 069 198 VVM S320 Stainless steel 3x400 V Part no 069 196 VVM S320 Enamel 3x400 V Part no 069 206 VVM S320 Copper 3x400 V Part no 069 195 4 NIBE S2125 IT S IN OUR NATURE ...

Страница 5: ... 6 UN NIBE S2125 5 IT S IN OUR NATURE CONTROL MODULES SMO S40 Control module Part no 067 654 ...

Страница 6: ...MBOL KEY Meaning Symbol Shut off valve Tapping valve Non return valve Circulation pump Expansion vessel Filterball Pressure gauge P Safety valve Trim valve Reversing valve shunt Control module Air water heat pump Radiator system Domestic hot water Water heater EXPLANATION Connection heating medium out of S2125 XL1 Connection heating medium in to S2125 XL2 EB101 QM40 EB101 QZ2 EB101 QM1 EB101 FL10 ...

Страница 7: ...st on asphalt or shingle The lower edge of the evaporator must not be lower than the level of the average local snow depth The base should be at least 70 mm tall S2125 should not be positioned next to noise sensitive walls for example next to a bedroom Also ensure that the placement does not inconveni ence the neighbours S2125 must not be placed so that recirculation of the outdoor air is possible...

Страница 8: ...f a crane vehicle cannot be used the S2125 can be transported on an extended sack truck S2125 must be taken from its heaviest side and two people are required to lift S2125 LIFT FROM THE PALLET TO FINAL POSITIONING Before lifting remove the packaging and the securing strap to the pallet Place lifting straps around each machine foot Lifting from the pallet to the base requires four persons one for ...

Страница 9: ...utrymme bakom Fritt utrymme framför dock 1000 mm för ev framtida service Min avstånd vid användning av flera F2300 600 mm 1000 mm 400 mm Minimalt fritt utrymme 600mm Minimalt fritt utrymme Minimum free space Minimum free space Minimum distance during use of several S2125 600 mm 600 mm At least 1 000 mm 400 mm Free space in front for any future servicing 350 500 mm Free space behind The space behin...

Страница 10: ...condensate drip tray is not included To ensure the function the access ory KVR 11 should be used The condensation water up to 50 litres 24 hrs that collects in the trough should be routed away by a pipe to an appropriate drain it is recommended that the shortest outdoor stretch possible is used The section of the pipe that can be affected by frost must be heated by the heating cable to prevent fre...

Страница 11: ...tions When routing pipes indoors condensation water pipes must be insulated against condensation Route the pipe downward from S2125 The condensation water pipe must have a water seal to prevent air circulation in the pipe Pipe routing indoors is not included Gutter drainage LEK S2125 Frostfritt djup Frost free depth Water seal Route the pipe downward from S2125 The condensation water pipe must hav...

Страница 12: ...o enable defrosting For the optimum operation of S2125 a minimum available water volume of 10 litres multiplied by the size number is recommended E g S2125 12 10 litres x 12 120 litres This applies indi vidually to heating and cooling systems PIPE COUPLING HEATING MEDIUM You can find a list of compatible products in the section Compatible indoor modules VVM and control modules SMO There is a diffe...

Страница 13: ... and wiring must be carried out in accordance with national provisions Disconnect S2125 before insulation testing the house wiring If a miniature circuit breaker is used this must have at least triggering characteristic C See section Technical specifications in the Installer Manual for S2125 If the building is equipped with an earth fault breaker S2125 should be equipped with a separate one S2125 ...

Страница 14: ...ant during windy conditions and or in the event of snow as the grilles can become blocked Also check that drain holes in the bottom panel are free from dirt and leaves Regularly check that condensation is routed away cor rectly through the condensation pipe Ask your installer for assistance if required KEEP FREE OF SNOW AND ICE S2125 S2125 S2125 S2125 LEK LEK LEK LEK Prevent snow from building up ...

Страница 15: ...ng a damp cloth Care must be exercised so that the heat pump is not scratched when cleaning Avoid spraying water into the grilles or the sides so that water penetrates into S2125 Prevent S2125 coming into contact with alkaline cleaning agents NIBE S2125 15 IT S IN OUR NATURE ...

Страница 16: ...ired value OWN CURVE The indoor module control module have pre pro grammed non linear heating curves It is also possible to create your own defined curve This is a partially linear curve with a number of break points You select break points and the associated temperatures Hot water production Hot water charging starts when the temperat ure has fallen to the set start temperature Hot water charging...

Страница 17: ...t from this you can choose two premium services for a fixed annual fee the fee varies depending on the functions selected MOBILE APPS FOR MYUPLINK The mobile apps can be downloaded free of charge from where you usually download your mobile apps Logging into the mobile app is performed using the same account details as on myuplink com NIBE SMART PRICE ADAPTION Smart Price Adaption is not available ...

Страница 18: ...5 8 Maximal och mininimal uppvärmningseffekt Framledningstemperatur 35 C Framledningstemperatur 45 C Framledningstemperatur 55 C Utomhustemperatur C Uppvärmningseffekt kW Tyst läge framledningstemperatur 35 C Tyst läge framledningstemperatur 55 C Heating output kW Outdoor temperature C Flow line temperature 35 C Flow line temperature 45 C Flow line temperature 55 C Silent mode supply temperature 3...

Страница 19: ...2 0 0 10 0 12 0 8 0 6 0 4 0 2 0 15 20 25 30 35 40 45 Utomhustemperatur C S2125 Maximal och mininimal kyleffekt Kyleffekt kW Framledningstemperatur 18 C Framledningstemperatur 7 C Cooling output kW Supply temperature 18 C Supply temperature 7 C Outdoor temperature C NIBE S2125 19 IT S IN OUR NATURE ...

Страница 20: ...Dimensions S2125 1128 1054 220 40 52 Ø52 57 11 471 37 67 1043 745 68 62 556 621 Ø40 122 174 40 52 57 118 80 471 37 67 1043 745 68 62 556 96 122 20 NIBE S2125 IT S IN OUR NATURE ...

Страница 21: ...lues 2 m 6 m 10 m LEK 2 m 6 m 10 m Sound pressure at distance m 2 Sound power1 10 9 8 7 6 5 4 3 2 1 24 25 26 27 28 5 30 32 34 5 38 44 49 Nominal sound value S2125 8 30 31 32 33 34 5 36 38 40 5 44 50 55 Max sound value 25 26 27 28 29 5 31 33 35 5 39 45 50 Max sound value silent mode 24 25 26 27 28 5 30 32 34 5 38 44 49 Nominal sound value S2125 12 34 35 36 37 38 5 40 42 44 5 48 54 59 Max sound valu...

Страница 22: ...verage climate 35 C 55 C Europe 4 20 3 40 4 10 3 20 4 20 3 40 4 10 3 20 SCOP cold climate 35 C 55 C 6 30 4 60 6 30 4 50 6 30 4 60 6 30 4 50 SCOP warm climate 35 C 55 C Energy rating average climate2 A A A A A A A A The product s room heating efficiency class 35 C 55 C3 A A The system s room heating efficiency class 35 C 55 C4 Electrical data 400 V 3N 50 Hz 400 V 3N 50 Hz 230 V 50 Hz 230 V 50 Hz Ra...

Страница 23: ...defrosting according to EN 14511 at heating medium supply corresponding to DT 5 K at 7 45 2 The reported efficiency of the package also takes the controller into account If an external supplementary boiler or solar heating is added to the package the overall efficiency of the package should be recalculated 3 Scale for the product s room heating efficiency class A to G Control module model SMO S 4 ...

Страница 24: ...list available at nibe eu Not all accessories are available on all markets Condensation water pipe Condensation water pipe different lengths LEK KVR 11 10 1 metres Part no 067 823 KVR 11 30 3 metres Part no 067 824 KVR 11 60 6 metres Part no 067 825 24 NIBE S2125 IT S IN OUR NATURE ...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...gy Systems All product illustrations facts and data are based on current information at the time of the publication s approval NIBE Energy Systems makes reservations for any factual or printing errors in this product sheet 2021 NIBE ENERGY SYSTEMS WS name Gemensamt WS version a922 working edition Publish date 2021 10 05 06 02 ...

Отзывы: