Standby mode

To be able to produce heat when the heat transfer system 
is disconnected, or during servicing, the heat pump can be 
set to standby mode, in which case heating is produced 
only by the immersion heater. Hot water is not produced 
in standby mode. The compressor and heat transfer system 
are then shutoff and only the heat medium pump and the 
immersion heater are active. The temperature is control-
led by the thermostat (3). To select standby mode, set the 
switch (8) to “        ”. 
Electrical step 2 is connected in standby mode and the 
display is off.

8

Alarm

In the event of an alarm, the status lamp lights red, the 
background lighting in the display flashes and the infor-
mation is shown in the display depending on the error. An 
alarm log is created with each alarm containing a number 
of temperatures, times and the status of outputs. The four 
most recent alarms are saved on menu 9.5.0 - 9.8.0. 
The alarms can only be acknowledged by switching off the 
heat pump for a few seconds and then starting it again. 
This is done using switch (8). 
When the alarm cannot be reset using the switch (8), the 
operating mode, “Only additional heat”, can be activated 
in menu 9.2.4 to have access to hot water gain. 

Additional heat only 

(electric boiler mode)

Compressor and brine pump blocked. The function can 
be activated/deactivated by pressing the “operating mode 
button” for 7 seconds.

The heat pump now produces heat and hot water with the 
built-in immersion heater.

The product’s serial number should always 

be stated in all correspondence with NIBE. 