Display explanation
C0
F0
H0
S1
01
Compressor: C
Shows the present compressor status.
Compressor off, circulation pump off
C0
Flashes when the compressor wants to start but
is prevented by the time conditions or high return
temperature.
C
Compressor on, circulation pump on
C1
Compressor off, circulation pump on
CC
Defrosting in progress
CD
Fan: F
The fan has two speeds, high or low. The fan is con-
trolled by the ambient temperature. The lower speed
is used when the ambient temperature is too high to
limit the output. At an ambient temperature lower
than the temperature in the table below the fan speed
is changed to high.
Ambient temperature (°C)
Type
20
7 kW
20
9 kW
Fan off
F0
Fan on, low speed
F1
Fan on, high speed
F2
Heater: H
The compressor heater is always active when the
compressor is switched off.
The condensation water trough heater is connected
during defrosting when the ambient temperature falls
below or is equal to 2.5 °C.
If the collar heater is permitted (channel A14), it activ-
ates every third defrosting, when the ambient temper-
ature lies below 2 °C.
Compressor heater off
Condensation water trough heater off
Collar heater off
H0
Compressor heater on
H1
Condensation water trough heater on
H2
Compressor heater on
Condensation water trough heater on
H3
Collar heater on
H4
Compressor heater on
Collar heater on
H5
Condensation water trough heater on
Collar heater on
H6
Compressor heater on
Condensation water trough heater on
Collar heater on
H7
Channel: S1
Shows the current channel. Change channels using the
Plus button or the Minus button.
Value: 01
Shows the current value. Increase/decrease value using
the plus button respective minus button.
27
Chapter 7 |
Control - Introduction
NIBE™ F2030
Содержание F2030
Страница 1: ...Installer manual LEK NIBE F2030 Air water heat pump IHB GB 1540 4 231115...
Страница 2: ......
Страница 13: ...Removing the side cover LEK APH 11 Chapter 2 Delivery and handling NIBE F2030...
Страница 32: ...5 The temperature on the flow temperature sensor falls below 4 C NIBE F2030 Chapter 7 Control Introduction 30...
Страница 48: ...Electrical circuit diagram NIBE F2030 Chapter 11 Technical data 46...
Страница 49: ...47 Chapter 11 Technical data NIBE F2030...
Страница 50: ...NIBE F2030 Chapter 11 Technical data 48...
Страница 51: ...49 Chapter 11 Technical data NIBE F2030...
Страница 54: ......