INSTALLATION INSTRUCTIONS
ESV 22
General
This accessory is used when NIBE ACVM 270 is installed in
houses with two different heating systems that require dif-
ferent flow line temperatures, for example, in cases where
the house has both a radiator system and an under floor
heating system. In the following text Heating system 1 covers
the system that requires the greater temperature and that is
connected to the normal flow line respectively return line
connection. Heating system 2 covers the heating system that
works at the lower temperature.
The water flow in the two heating systems should not exceed
2050 l/h (0,57 l/s).
NOTE
This accessory also requires accessory ACK 22.
Contents
3 wire circulation pump
1 x
Cable ties
4 x
Heating pipe paste
2 x
Insulation tape
1 x
Flat gasket
2 x
Round sleeve
4 x
Circulation pump Union 3-speed, EP21-GP20
1 x
Ball valve M Swivel nut
2 x
3-way valve
1 x
Aluminium tape (pieces)
2 x
Temperature sensor, EP21-BT2 (flow sensor), EP21-
BT3 (return sensor)
2 x
Control motor, EP21-QN25
1 x
9
ESV 22
GB