Energy labelling
NIBE
Supplier
ERS S10-400
Model
Average: -37.5
Cold: -75.0
Warm: -13.4
kWh/(m
2
year)
Specific energy consumption (SEC)
A
Energy efficiency class
RVU, Bidirectional
Declared typology
Variable speed drive
Type of drive
Recuperative
Type of heat recovery system
86
Thermal efficiency of heat recovery
394
m
3
/h
Maximum air flow rate
163
W
Electric power input of the fan drive at maximum flow
rate
47
dB
Sound power level (LWA)
0.077
m
3
/s
Reference flow rate
50
Pa
Reference pressure difference
0.242
W/m
3
/h
Specific power input (SPI)
Clock control (0.95)
Control factor and control typology
Internal: 2.0
External: 1.6
%
External leakage rates
See user manual.
Information about filter warning
See the "Ventilation connections" section.
Information about supply/exhaust grilles in the facade
See the "Recovery" section.
This installer manual can also be accessed at
.
Information about pre-/disassembly
318
kWh/year
The annual electricity consumption
Average: 4,383
Cold: 8,770
Warm: 2,027
kWh
prim/year
Annual heating saved, kWh primary energy per year
25
Chapter 10 | Technical data