Nibe ERS S10-400 Скачать руководство пользователя страница 1

IHB EN 2110-3
531299

INSTALLER MANUAL

HRV unit
NIBE ERS S10-400

LEK

Содержание ERS S10-400

Страница 1: ...IHB EN 2110 3 531299 INSTALLER MANUAL HRV unit NIBE ERS S10 400 LEK...

Страница 2: ...S series S1255 F series...

Страница 3: ...s 12 Condensation water drain 13 General ventilation connections 13 Ventilation flow 13 Adjusting ventilation 13 Dimensions and ventilation connections 14 5 Electrical connection 14 Overview accessory...

Страница 4: ...e hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This is an original manual It may not be translated withou...

Страница 5: ...ing to the in staller who installed the product or to special waste stations When disposing of the product its constituent materials and components e g compressors fans circulation pumps and circuit b...

Страница 6: ...issioned The inspection must be carried out by a suitably qualified person In addition fill in the page for the installation data in the User Manual Date Signa ture Notes Description Electricity page...

Страница 7: ...ing the covers FRONT COVER 1 Lift the front cover upwards slightly 2 Pull the hatch towards yourself LEK Removing parts of the insulation FRONT INSULATION The insulation in the front must be removed t...

Страница 8: ...e may be a problem Wherever the unit is located walls to sound sensitive rooms should be fitted with sound insulation Condensation water comes from the HRV unit A condensation outlet with a water seal...

Страница 9: ...n damper is recommended to prevent vibration being transferred 1 Install the enclosed bracket to the wall 2 Install ERS S10 on the brackets LEK 3 Screw ERS S10 firmly into place on the bracket LEK 9 C...

Страница 10: ...LEK GQ2 XL31 XL34 XL32 XL33 AA5 GQ3 WM5 EP26 XL40 HQ11 HQ10 QN37 W102 W101 BT21 BT22 BT20 BT23 PZ1 NIBE ERS S10 400 Chapter 3 Design of the HRV unit 10 S Design of the HRV unit...

Страница 11: ...act air BT21 Temperature sensor supply air BT22 Temperature sensor outdoor air BT23 Electrical components Accessory card AA5 Cord with connection plug W101 Communication cable W102 Ventilation Heat ex...

Страница 12: ...ally used for a wash basin connec tion G32 CLEANING THE CONDENSATION WATER DRAIN Condensation forms when ERS S10 is working This condensation is led off and collected in the condensation water drain A...

Страница 13: ...onnect ing the air ducts EXHAUST AIR DUCT KITCHEN FAN Exhaust air duct kitchen fan must not be connected to ERS S10 To prevent food vapour being transferred to ERS S10 the distance between the kitchen...

Страница 14: ...high voltage cables The minimum area of communication and sensor cables to external connections must be 0 5 mm up to 50 m for example EKKX LiYY or equivalent For electrical wiring diagram see page 26...

Страница 15: ...A B GND A B GND Main product Accessory 1 Accessory 2 The terminal block AA2 X30 is upright on S1155 CONNECTING TO CONTROL MODULE ERS S10 contains an accessory board AA5 that con nects directly to the...

Страница 16: ...s You can have up to 4 ERS S10 in the same installation each ERS S10 is given a unique setting ON 1 2 3 4 5 6 7 8 ERS S10 no 2 ON 1 2 3 4 5 6 7 8 ERS S10 no 1 ON 1 2 3 4 5 6 7 8 ERS S10 no 4 ON 1 2 3...

Страница 17: ...installation it is im portant that a ventilation adjustment is ordered and permitted Caution An incorrectly set ventilation flow can damage the house and may also increase energy con sumption NOTE Or...

Страница 18: ...1 FAN SPEED Alternatives normal and speed 1 speed 4 The ventilation in the accommodation can be temporarily increased or reduced here When you have selected a new speed a clock starts a count down Whe...

Страница 19: ...d further Caution Only the heat recovery is stopped not the ventilation Temp stop of heat recovery Here you set the outside temperature at which ventilation recovery is to stop Min diff ind temp outd...

Страница 20: ...aution A schedule repeats according to the selected setting e g every Monday until you go into the menu and switch it off MENU 7 4 SELECTABLE IN OUTPUTS Select here whether you want to activate fan sp...

Страница 21: ...ch choke or blocked ventilation device Check and clean the ventilation devices Fan speed in reduced mode Enter the main product s menu 1 2 1 and select normal External switch for changing the fan spee...

Страница 22: ...ER EAH 20 In cold weather EAH heats the incoming outdoor air slightly to prevent the condensation in ERS S10 from freezing to form ice EAH should be used in houses where the outdoor temperature can be...

Страница 23: ...Dimensions 900 44 600 4 x 160 G32 308 146 146 278 206 146 630 23 Chapter 10 Technical data NIBE ERS S10 400 S Technical data...

Страница 24: ...r drain Dimensions and weight A Efficiency class3 2 4 m Length supply cable 2 0 m Length communication cable 600 mm Width 900 mm Height 630 mm Depth 40 kg Weight 066 163 Part No 1 277 m3 h 77 l s at 5...

Страница 25: ...ence flow rate 50 Pa Reference pressure difference 0 242 W m3 h Specific power input SPI Clock control 0 95 Control factor and control typology Internal 2 0 External 1 6 External leakage rates See use...

Страница 26: ...Part Specification Sheet 051145 2 Page 2 2 Created 2019 07 05 13 28 0 001 JOV 2019 07 05 Production GBN 2016 04 27 WIRING DIAGRAM ERS S10 10 400 ELSCHEMA ERS S10 10 400 051145 2 NIBE ERS S10 400 Chap...

Страница 27: ...nections 35 Condensation water drain 36 General ventilation connections 36 Ventilation flow 36 Adjusting ventilation 36 Dimensions and ventilation connections 37 15 Electrical connection 37 Overview a...

Страница 28: ...e hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This is an original manual It may not be translated withou...

Страница 29: ...ing to the in staller who installed the product or to special waste stations When disposing of the product its constituent materials and components e g compressors fans circulation pumps and circuit b...

Страница 30: ...ssioned The inspection must be carried out by a suitably qualified person In addition fill in the page for the installation data in the User Manual Date Signa ture Notes Description Electricity page 3...

Страница 31: ...F1345 F1355 Removing the covers FRONT COVER 1 Lift the front cover upwards slightly 2 Pull the hatch towards yourself LEK Removing parts of the insulation FRONT INSULATION The insulation in the front...

Страница 32: ...sation water comes from the HRV unit A condensation outlet with a water seal must be in stalled and routed to an internal drain The HRV unit s installation area always has to have a temperature of at...

Страница 33: ...LEK GQ2 XL31 XL34 XL32 XL33 AA5 GQ3 WM5 EP26 XL40 HQ11 HQ10 QN37 W102 W101 BT21 BT22 BT20 BT23 PZ1 33 Chapter 3 Design of the HRV unit NIBE ERS S10 400 F Design of the HRV unit...

Страница 34: ...act air BT21 Temperature sensor supply air BT22 Temperature sensor outdoor air BT23 Electrical components Accessory card AA5 Cord with connection plug W101 Communication cable W102 Ventilation Heat ex...

Страница 35: ...ally used for a wash basin connec tion G32 CLEANING THE CONDENSATION WATER DRAIN Condensation forms when ERS S10 is working This condensation is led off and collected in the condensation water drain A...

Страница 36: ...onnect ing the air ducts EXHAUST AIR DUCT KITCHEN FAN Exhaust air duct kitchen fan must not be connected to ERS S10 To prevent food vapour being transferred to ERS S10 the distance between the kitchen...

Страница 37: ...high voltage cables The minimum area of communication and sensor cables to external connections must be 0 5 mm up to 50 m for example EKKX LiYY or equivalent For electrical wiring diagram see page 48...

Страница 38: ...00 AA3 X4 F1145 F1155 CONNECTING TO CONTROL MODULE ERS S10 contains an accessory board AA5 that con nects directly to the control module on its accessory board terminal block AA5 X4 The communication...

Страница 39: ...s You can have up to 4 ERS S10 in the same installation each ERS S10 is given a unique setting ON 1 2 3 4 5 6 7 8 ERS S10 no 2 ON 1 2 3 4 5 6 7 8 ERS S10 no 1 ON 1 2 3 4 5 6 7 8 ERS S10 no 4 ON 1 2 3...

Страница 40: ...set at installation it is im portant that a ventilation adjustment is ordered and permitted Caution An incorrectly set ventilation flow can damage the house and may also increase energy con sumption N...

Страница 41: ...ir temp Setting range 5 30 C Default value 25 C product Setting range ERS S10 ERS 20 ERS 30 Factory setting ERS 20 ERS 30 action level monitor Setting range off blocked level monitor Default value lev...

Страница 42: ...d the fans stop when the input closes If blocked is selected text in operating info shows that the input is closed The fans stop until the input is open TIP When ERS S10 is activated the other ventila...

Страница 43: ...much choke or blocked ventilation device Check and clean the ventilation devices Fan speed in reduced mode Enter the main product s menu 1 2 and select normal External switch for changing the fan spee...

Страница 44: ...ERS S10 from freezing to form ice EAH should be used in houses where the outdoor temperature can be continuously lower than 5 C EAH 20 1800 300 1800 W Part no 067 603 TOP CABINET TOC 40 Top cabinet t...

Страница 45: ...Dimensions 900 44 600 4 x 160 G32 308 146 146 278 206 146 630 45 Chapter 10 Technical data NIBE ERS S10 400 F Technical data...

Страница 46: ...r drain Dimensions and weight A Efficiency class3 2 4 m Length supply cable 2 0 m Length communication cable 600 mm Width 900 mm Height 630 mm Depth 40 kg Weight 066 163 Part No 1 277 m3 h 77 l s at 5...

Страница 47: ...ence flow rate 50 Pa Reference pressure difference 0 242 W m3 h Specific power input SPI Clock control 0 95 Control factor and control typology Internal 2 0 External 1 6 External leakage rates See use...

Страница 48: ...Part Specification Sheet 051145 2 Page 2 2 Created 2019 07 05 13 28 0 001 JOV 2019 07 05 Production GBN 2016 04 27 WIRING DIAGRAM ERS S10 10 400 ELSCHEMA ERS S10 10 400 051145 2 NIBE ERS S10 400 Chap...

Страница 49: ...mation 4 28 Recycling 5 29 Inspection of the installation 6 30 Installation area 8 32 M Marking 5 29 Menu system 18 41 Mounting 9 32 P Pipe and ventilation connections Exhaust air duct 13 36 Program s...

Страница 50: ......

Страница 51: ...e fi NORWAY NETHERLANDS GREAT BRITAIN ABK Qviller AS Brobekkveien 80 0582 Oslo Tel 47 23 17 05 20 post abkqviller no nibe no NIBE Energietechniek B V Energieweg 31 4906 CG Oosterhout Tel 31 0 168 47 7...

Страница 52: ...BE Energy Systems All product illustrations facts and data are based on the available information at the time of the publication s approval NIBE Energy Systems makes reservations for any factual or pr...

Отзывы: