Activating EMK 310
Activation of EMK 310 occurs the
firs
t time that a
flow
is measured. Energy measurement is displayed in the
service information for your main unit.
For main products
wit
h
softwa
re version 6869 or later,
check that the correct
flow
sensor is selected by going
to the menu 5.3.20 -
"flow
sensor".
Select EMK300/310 if it is not preset.
When EMK 310 is activated, it is
show
n in menu 3.1 -
"service info" and the menu
wit
h the registered values
becomes available.
service info 3.1
confi
g EB15
inc.
power
int. add
heat med. pump
charge pump
display type
flow
sensor
0
3x400 V
12 kW
Wilo Yonos Para 7.0
Wilo Yonos Para 7.0
EMK300/310
flow
sensor
service info 3.1
climate system 1
heat meter
heating, compr. only.
hotwate
r, compr. only.
pool, compr. only.
cooling, compr. only.
heating, int. add. incl.
h
w
, incl. int. add
BF1
EB15
12.4 l/min
0 kWh
0 kWh
0 kWh
0 kWh
0 kWh
0 kWh
Caution
Also see the Installer manual for VVM 310.
Technical data EMK 310
5,0 – 85
l/min
Measurement range
0,1 – 18
kPa
Pressure drop
-15 – +85
°C
Ambient temperature
<125
°C
Medium temperature
5 ±5%
VDC
Supply
0,1 – 4,75
V
Signal
067 246
Part No.
12
GB