English
General
This accessory is used to dock a F730 to a VPB 200 in
houses that have a large hot water demand.
Caution
The heat pump must have software version
7696 or later. Visit www.nibeuplink.com and
click on the tab "Software" to download the
latest software to your installation.
Caution
F730 does not have a mixer valve (FQ1). If the
factory setting is changed so that the hot water
temperature can exceed 60 °C, install a mixer
valve, see the Installer Manual for F730.
TIP
See the installation manuals for F730 and
VPB 200 for more information about the
products and their installation. Documentation
can be downloaded from www.nibe.eu.
Contents
Unit box (AA25)
1 x
Shut-off valve (QM35)
1 x
Non-return valve (RM1)
1 x
Cable ties
2 x
Plastic clips
6 x
Screw M5x9, torx
4 x
Temperature sensor for indoor use (BT6), (BT7)
2 x
Heating pipe paste
2 x
Reversing valve (QN28)
1 x
Component location unit box (AA25)
LEK
AA5-X2
AA5-X9
AA5-X4
AA5
SF1
Electrical components
Switch
SF1
Accessory card
AA5
Terminal block, sensors and external block-
ing
AA5-X2
Terminal block, communication
AA5-X4
Terminal block, reversing valve
AA5-X9
Designations in component locations according to
standard IEC 81346-1 and 81346-2.
DEW 41 | GB
10