CONNECTION OF THE MIXER VALVE (QZ1-FQ3)
Connect the mixing valve motor (FQ3) to AA5-X9:6 (230 V,
open), AA5-X9:5 (N) and AA5-X9:4 (230 V, close).
1
2
3
4
5
6
7
8
9
AA5-X9
1
M
External
AA25
FQ3
Open
Close
CONNECTION OF AUXILIARY RELAY FOR
ADDITIONAL HEAT IN TANK
Connect the auxiliary relay for switching the additional heat
on and off to AA5-X9:2 (230 V) and AA5-X9:1 (N).
1
2
3
4
5
6
7
8
9
AA5-X9
L
N
A2
A1
Extra
hot water
External auxiliary relay
AA25
External
DIP SWITCH
The DIP switch (S2) on the accessory board (AA5) must be
set as follows.
3
2
1
ON
4
7
6
5
8
PROGRAM SETTINGS
Activating AXC 40 can be performed via the start guide or
directly in the menu system.
The main product’s software must be the latest version.
START GUIDE
The start guide appears upon first start-up after heat pump
installation, but is also found in menu 7.7.
MENU SYSTEM
If you do not make all settings via the start guide or need to
change any of the settings, this can be done in the menu
system.
Menu 7.2.1 - Add/remove accessories
Here, you state which accessories are installed for the
compatible product.
To identify connected accessories automatically, select
"Search for accessories". It is also possible to select accessor-
ies manually from the list.
Menu 2.5 - Hot water circulation
Operating time
Setting range: 1 – 60 min
Downtime
Setting range: 0 – 60 min
Period
Active days
Setting range: Monday – Sunday
Start time
Setting range: 00:00 – 23:59
Stop time
Setting range: 00:00 – 23:59
Set hot water circulation for up to five periods per day here.
During the set periods, the hot water circulation pump will
run according to the settings above.
"Operating time" decide how long the hot water circulation
pump must run per operating instance.
"Downtime" decide how long the hot water circulation pump
must be stationary between operating instances.
"Period" Here, you set the period of time during which the
hot water circulation pump will run, by selecting Active days,
Start time and Stop time.
NOTE
Hot water circulation is activated in menu 7.4
"Selectable in/outputs" or 7.2.8 "Hot water comfort
(AXC)".
19
AXC 40 S-series | EN
S
Содержание AXC 40
Страница 1: ...AXC 40 Installer Manual Accessory card LEK IHB 2236 1 731176 ...
Страница 2: ...S series S1255 4 S series F series 43 F series ...
Страница 12: ...ELECTRICAL CIRCUIT DIAGRAM WIRING DIAGRAM SHUNT CONTROL ELSCHEMA SHUNTSTYRD 051055 8 AXC 40 S series EN 12 S ...
Страница 25: ...ELECTRICAL CIRCUIT DIAGRAM WIR DIA GROUND WATER PUMP ELSCHEMA GRUNDV PUMP 051054 8 25 AXC 40 S series EN S ...
Страница 51: ...ELECTRICAL CIRCUIT DIAGRAM WIRING DIAGRAM SHUNT CONTROL ELSCHEMA SHUNTSTYRD 051055 8 51 AXC 40 F series EN F ...
Страница 63: ...ELECTRICAL CIRCUIT DIAGRAM WIR DIA GROUND WATER PUMP ELSCHEMA GRUNDV PUMP 051054 8 63 AXC 40 F series EN F ...