23
We reserve the right to make technical changes
83050406cUK – Translation of the operating manual
NIBE
TM
AP-AW10
notICe.
To ensure good seating of the motor on the
valve, make sure that the u-bolt with the reduc-
tion is not pushed past the lug, because then the
motor will not be held securely on the valve!
In order to be supported securely, the u-bolt must
bear with both ends against the lug.
bleed the heating circuit and hot water circuit…
Ap-AW10-6c-8c
1 bleed valve
Ap-AW10-10c
1 bleed valve
1 permanent bleeder
notICe.
once the heat pump, the heating circuit and the
hot water circuit have been rinsed, the bleed
program of the heating and heat pump regulator
must be started, after the control element has
been mounted.
If no further steps follow, install the bottom front
panel.
proCeed as follows for the
ap-aW10-12C
:
If unit is closed, open bottom front panel…
“Transport with a hand truck”
loosen the quick-release screws for the lower front
panel (= control side), remove lower front panel and
set aside…
Rinse and fill unit via the filling and emptying valve…