Niagara NPB-2X-485 Скачать руководство пользователя страница 2

RS-485 Option Card Install Sheet

Updated: January 16, 2012

Part Number 11873  Rev 1.1

Mounting

Mounting

 

2

Note

RS

485

 

bias

 

resistors

 

are

 

different

 

than

 

“termination

 

resistors”,

 

externally

 

installed

 

at

 

the

 

two

 

physical

 

ends

 

of

 

a

 

daisychained

 

RS

485

 

trunk,

 

across

 

the

 

“+”

 

and

 

“–”

 

terminals.

 

Termination

 

resistors

 

are

 

typically

 

100

 

or

 

120

 

ohm

 

value

 

resistors.

Whenever

 

termination

 

resistors

 

are

 

used,

 

RS

485

 

biasing

 

is

 

typically

 

required.

To

 

enable

 

biasing,

 

install

 

two

 

2

pin

 

jumper

 

blocks

 

on

 

that

 

port’s

 

jumper

 

header,

 

as

 

shown

 

in

 

Figure

 

2

.

 

To

 

turn

 

off

 

biasing,

 

remove

 

both

 

2

pin

 

jumper

 

blocks

 

from

 

that

 

port’s

 

header

 

(

 

the

 

factory

shipped

 

state).

Mounting

Warning

Power

 

to

 

the

 

controller

 

must

 

be

 

OFF

 

when

 

installing

 

or

 

removing

 

option

 

cards,

 

or

 

damage

 

will

 

occur!

 

Also,

 

you

 

must

 

be

 

very

 

careful

 

to

 

plug

 

any

 

option

 

card

 

into

 

its

 

connector

 

properly

 

(pins

 

aligned).

Mount

 

the

 

NPB

2X

485

 

option

 

card

 

in

 

either

 

of

 

the

 

option

 

card

 

slots

 

of

 

the

 

JACE,

 

as

 

needed.

 

Note

 

the

 

T

202/602

XPR

 

series

 

has

 

only

 

one

 

option

 

card

 

slot.

See

 

“Preparation,”

 

page

 

1

 

for

 

details

 

about

 

RS

485

 

resistor

 

biasing,

 

available

 

on

 

newer

 

option

 

cards.

See

 

“COM

 

Port

 

Usage,”

 

page

 

3

 

for

 

details

 

about

 

JACE

 

COM

 

port

 

assignments.

Procedure 1

Mounting NPB-2X-485 option card on a JACE.

1.

Remove power

 

from

 

the

 

JACE—see

 

the

 

previous

 

Warning

.

 

Wait

 

for

 

all

 

LEDs

 

on

 

the

 

unit

 

to

 

be

 

Off.

2.

Remove

 

the

 

JACE

 

cover

 

or

 

covers

 

(T

202/602

XPR).

 

For

 

all

 

but

 

the

 

T

202/602

XPR,

 

press

 

in

 

the

 

four

 

tabs

 

on

 

both

 

ends

 

of

 

the

 

unit,

 

and

 

lift

 

the

 

cover

 

off.

Note

If

 

accessory

 

modules

 

are

 

plugged

 

into

 

the

 

JACE,

 

you

 

may

 

need

 

to

 

slide

 

them

 

away

 

from

 

the

 

unit

 

to

 

get

 

to

 

the

 

cover

 

tabs.

For

 

the

 

T

202/602

XPR,

 

first

 

remove

 

the

 

right

 

cover,

 

then

 

the

 

left

 

cover,

 

retaining

 

the

 

two

 

screws

 

that

 

secure

 

each

 

cover.

3.

If

 

a

 

T

200/600

 

series

 

or

 

Security

 

JACE,

 

remove

 

the

 

battery

 

and

 

bracket

 

assembly

 

by

 

taking

 

out

 

the

 

screws

 

holding

 

it

 

in

 

place,

 

setting

 

screws

 

aside

 

for

 

later.

 

See

 

Figure

 

3

.

Figure 3

Remove screws and battery assembly.

Note

The

 

tie

 

wrap

 

on

 

the

 

battery

 

pack

 

should

 

have

 

its

 

lock

 

“knot”

 

on

 

top

,

 

as

 

shown

 

in

 

Figure

 

3

.

 

If

 

not,

 

cut

 

and

 

remove

 

the

 

tie,

 

then

 

re

install

 

another

 

tie

 

wrap

 

with

 

its

 

lock

 

tab

 

on

 

top.

 

(

Tie

 

lock

 

at

 

bottom

 

interferes

 

with

 

option

 

card

).

4.

Remove

 

the

 

blanking

 

end

 

plate

 

for

 

the

 

slot

 

you

 

are

 

installing

 

the

 

option

 

card

 

into.

(Retain

 

the

 

blanking

 

end

 

plate

 

in

 

case

 

the

 

option

 

card

 

must

 

be

 

removed

 

at

 

a

 

later

 

date.)

Note

Slot

 

2

 

option

 

card

 

installation

 

in

 

a

 

T

700

 

controller

 

requires

 

careful

 

attention!

 

See

 

the

 

T

700

 

Mounting

 

and

 

Wiring

 

Guide

 

for

 

more

 

details.

 

This

 

document

 

focuses

 

on

 

installation

 

in

 

a

 

T

200/600

 

series

 

controller.

5.

Carefully

 

insert

 

the

 

pins

 

of

 

the

 

NPB

2X

485

 

into

 

the

 

socket

 

of

 

the

 

appropriate

 

option

 

card

 

slot.

 

The

 

mounting

 

holes

 

on

 

the

 

option

 

board

 

should

 

line

 

up

 

with

 

the

 

standoffs

 

on

 

the

 

base

 

board.

 

If

 

they

 

do

 

not,

 

the

 

connector

 

is

 

not

 

properly

 

aligned.

 

Press

 

until

 

the

 

option

 

card

 

is

 

completely

 

seated.

6.

Place

 

the

 

custom

 

end

 

plate

 

that

 

came

 

with

 

the

 

NPB

2X

485

 

over

 

its

 

connector

 

(see

 

Figure

 

4

).

Screws (4)

Option 

Slot 2

 

Area

T-200/600

 

Blanking 

End Plate

Battery 
Assembly

(includes

cable and 
bracket)

Unplug 
battery here

Option 

Slot 1

 Area

Tie Wrap 

Lock 

(see 

Note

)

Содержание NPB-2X-485

Страница 1: ...ors Note An earlier NPB 2X 485 option card does not have Bias jumpers It operates like the newer option card in factory shipped state jumper blocks not installed no biasing Installing jumpers to enable biasing adds two onboard 3 3K ohm resistors into an RS 485 port s circuit from RS 485 to 5V from RS 485 to Ground Biasing sometimes improves RS 485 communications by eliminating indeterminate idle s...

Страница 2: ...t the cover off Note If accessory modules are plugged into the JACE you may need to slide them away from the unit to get to the cover tabs For the T 202 602 XPR first remove the right cover then the left cover retaining the two screws that secure each cover 3 If a T 200 600 series or Security JACE remove the battery and bracket assembly by taking out the screws holding it in place setting screws a...

Страница 3: ...r each port are described as follows TX yellow Transmit indicates that the JACE is sending data to a device connected on the RS 485 trunk RX green Receive indicates that the JACE is receiving data from a device connected on the RS 485 trunk COM Port Usage The NPB 2X 485 option card has two onboard UARTs and so adds two COM ports on the installed JACE controller The hosted station automatically res...

Страница 4: ... fea tures contained herein are covered by one or more U S or foreign patents This document may be copied by parties who are authorized to distribute Tridium prod ucts in connection with distribution of those products subject to the contracts that authorize such distribution It may not otherwise in whole or in part be copied photocopied reproduced translated or reduced to any electronic medium or ...

Отзывы: