12
|
ni.com
|
NI SMD-7611/7612 User Manual
Figure 13.
Connecting to Indexer with Differential Outputs
Enable Input
Connecting the Enable input as shown in Figure 14 causes the drive to disable when the relay is
closed and enable when the relay is open.
Figure 14.
Connecting Enable to a Switch or Relay
Connecting the Enable signal as shown in Figure 15 causes the drive to disable when the output
closes.
Figure 15.
Connecting a Second Drive to EN
Connecting the Enable signal as shown in Figure 16 causes the drive to disable when the
proximity sensor activates.
Figure 16.
Connecting an NPN Type Proximity Sensor to an Input