FE is an optional, device-dependent connection.
•
FE provides functional earth ground.
Note
For information about fuse ratings for the REM-11175, refer to the device
Connection Guidelines
•
Make sure that devices you connect to the REM-11175 are compatible with the module
specifications.
•
Push the wire into the terminal when using a solid wire or a stranded wire with a ferrule.
•
Open the terminal by pressing a screwdriver into the spring lever when using a stranded
wire without a ferrule.
Removing Components
Removing Spring Terminal Blocks
Complete the following steps to remove a spring-terminal block from the REM-11175.
1
3
2
1.
Press the locking latch to release the spring-terminal block.
2.
Tilt the block toward the center of the module.
3.
Remove the connector from the module.
Removing the REM-11175
Remove all connections before removing the REM-11175, either by disconnecting the cables
or removing the spring-terminal block.
What to Use
•
Flathead Screwdriver
What to Do
Complete the following steps to remove the REM-11175 from the DIN rail.
10
|
ni.com
|
REM-11175 Getting Started Guide