Safety

This product meets the requirements of the following standards of safety for electrical equipment 
for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Note

For UL and other safety certifications, refer to the product label or the 

Online 

Product Certification

 section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment 
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

FCC 47 CFR Part 15B: Class A emissions

ICES-001: Class A emissions

Note

In the United States (per FCC 47 CFR), Class A equipment is intended for use 

in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, 
Australia and New Zealand (per CISPR 11) Class A equipment is intended for use 
only in heavy-industrial locations.

Note

Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical 

equipment that does not intentionally generates radio frequency energy for the 
treatment of material or inspection/analysis purposes.

Note

For EMC declarations and certifications, and additional information, refer to 

the 

Online Product Certification

 section. 

CE Compliance

This product meets the essential requirements of applicable European Directives as follows:

2006/95/EC; Low-Voltage Directive (safety)

2004/108/EC; Electromagnetic Compatibility Directive (EMC)

Online Product Certification

To obtain product certifications and the Declaration of Conformity (DoC) for this product, visit 

ni.com/certification

, search by model number or product line, and click the appropriate 

link in the Certification column.

Содержание PXIe-8383mc

Страница 1: ...Powering Off the PXImc System 12 Software Installation and Configuration 12 Specifications 13 Worldwide Support and Services 16 About This Guide This document describes the features functions and ope...

Страница 2: ...ss PCIe The terms PCI Express and PCIe are interchangeable in this guide PXI Express chassis In this manual whenever a PXI Express chassis is referenced a CompactPCI Express chassis could be used inst...

Страница 3: ...gure 1 illustrates where the PXImc Logic Block is applied to join the Root Complexes of two systems Figure 1 PXImc System Diagram In the example shown the system on the right is designated as a PXImc...

Страница 4: ...em does not contain a PXImc Logic Block a NI PXIe 8383mc can be installed in the Primary System Host to create a Logical PXImc Device out of the sub system Tip Consolidating all NI PXIe 8383mc adapter...

Страница 5: ...3 NI PXIe 8383mc 153100x 02L Block Diagram The PXImc logic block consists of a non transparent bridge and all the associated circuitry necessary to work with clock references from both the Primary Sys...

Страница 6: ...operating the NI PXIe 8383mc in MC mode and using a NI PXIe 8384 for daisy chain purposes SW4 FACT USER Factory User Mode Switch The FACT USER switch shown in Figure 3 selects between two different me...

Страница 7: ...ion Table 1 describes the function of the front panel LEDs FACT USER Switch Factory User SW4 BAR No Size bytes Address Space Prefetchable FACT BAR 5 32M 32 bit Yes USER BAR 1 BAR 2 BAR4 BAR5 128M 64M...

Страница 8: ...grounding strap or by holding a grounded object Touch the antistatic package to a metal part of the computer chassis before removing the device from the package Remove the device from the package and...

Страница 9: ...jector rail Caution Do not raise the injector ejector handle as you insert the NI PXIe 8383mc It will not insert properly unless the handle is in its downward position so that it does not interfere wi...

Страница 10: ...nsparent bridge in the PXImc Logic Block needs time to self configure before the sub system on the other side of the cable link can connect to it Consolidating all NI PXIe 8383mc adapter modules into...

Страница 11: ...are still powered off Allow time for the operating system to begin loading before proceeding to the next step The three items that follow power sequence B in Figure 4 meet these criteria Caution Do n...

Страница 12: ...mproper power on sequence A reboot of the system that controls the NI PXIe 8383mc may be necessary to resolve this Tip In applications where the power sequence must be automated consider using product...

Страница 13: ...XIe 8384 products NI PXIe 8383mc 153100x 02L Note These specifications are typical at 25 C unless otherwise stated and are subject to change without notice Physical Dimensions 10 0 16 0 cm 3 9 6 3 in...

Страница 14: ...in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 limits Relative humidity range 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Opera...

Страница 15: ...uipment is intended for use in commercial light industrial and heavy industrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy in...

Страница 16: ...ental information refer to the Minimize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other...

Отзывы: