background image

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For telephone support in the United
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

telephone support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/

niglobal

 to access the branch office websites, which provide up-to-date contact information,

support phone numbers, email addresses, and current events.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at 

ni.com/trademarks

 for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help

»

Patents in your

software, the 

patents.txt

 file on your media, or the National Instruments Patent Notice at 

ni.com/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the Export Compliance Information at 

ni.com/legal/export-compliance

 for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2017 National Instruments. All rights reserved.

375635A-01

Apr17

Содержание PCI-5152

Страница 1: ...in a manner not described in this document Contents Electromagnetic Compatibility Guidelines 2 Verifying the System Requirements 2 Unpacking the Kit 2 Kit Contents 3 Other Equipment 3 Preparing the E...

Страница 2: ...ion Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Verifying the Syste...

Страница 3: ...l items not included in your kit to install or operate your device PXI Devices A PXI chassis a PXI SCXI combination chassis or a PXI CompactPCI chassis with a controller and the chassis documentation...

Страница 4: ...068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Maximum altitude 2 000 m at 25 C ambient temperature Pollution Degree 2 Indoor use onl...

Страница 5: ...slot pins on the chassis backplane for any bends or damage prior to installation Do not install a module if the backplane is damaged 4 Remove the black plastic covers from all the captive screws on th...

Страница 6: ...imize cooling air flow depending on your application 12 Power on the chassis Note For more information about maximizing cooling air flow refer to the Maintain Forced Air Cooling Note to Users included...

Страница 7: ...anufacturers use a securing lever made of plastic to secure PCI devices such a lever is unacceptable and must be removed Use the screw provided in the kit to screw down the device Otherwise you must u...

Страница 8: ...CH 0 CH 1 TRIG PFI 1 PFI 0 ACCESS ACTIVE CH0 CH1 TRIG PFI0 PFI1 Table 1 PXI PCI 5152 Front Panel Signal Connections Connector Description Function CH 0 CH 1 Standard BNC female connector Analog input...

Страница 9: ...PE 1 Launch MAX 2 In the configuration tree expand Devices and Interfaces to see the list of installed NI hardware Installed modules appear under the name of their associated chassis 3 Expand your Cha...

Страница 10: ...libration capabilities which you can access programmatically with NI SCOPE and your ADE or interactively with NI SCOPE SFP or MAX Related Information Making a Measurement on page 12 What Should I Do i...

Страница 11: ...Microsoft Visual C C Use examples located in the file directory Users Public Documents National Instruments NI SCOPE examples You can modify an NI SCOPE C example to create an application with Micros...

Страница 12: ...he acquisition display 5 If the SFP is not already running click Run Making a Measurement with LabVIEW 1 Launch LabVIEW 2 Select Help Find Examples 3 Open the example VI that you want to use by select...

Страница 13: ...to NI RTSI Cable and select the device you want to add For more information about connecting PCI devices refer to NI High Speed Digitizers Help Programming Reference NI TClk Synchronization Help Troub...

Страница 14: ...e Device Manager Operating System Description Windows 10 8 1 Right click the Start button and select Device Manager Windows 7 Select Start Control Panel Device Manager 5 If you are using a PXI or PXI...

Страница 15: ...o Next DISCOVER Services ni com services NI Community ni com community Support ni com support NI Oscilloscopes ni com oscilloscope CREATE LEARN Getting Started with LabVIEW Getting Started with LabWin...

Страница 16: ...hone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers em...

Отзывы:

Похожие инструкции для PCI-5152