NI NI-9237 Скачать руководство пользователя страница 4

Isolation, channel-to-channel

None

Isolation, channel-to-earth ground

Up to 3,000 m

Continuous

60 VDC, Measurement Category I

Withstand

1,000 Vrms, verified by a 5 s dielectric withstand test

Up to 5,000 m

Continuous

60 VDC, Measurement Category I

Withstand

860 Vrms, verified by a 5 s dielectric withstand test

Safety Guidelines for Hazardous Locations

The NI-9237 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous

locations; Class I, Zone 2, AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations;

and nonhazardous locations only. Follow these guidelines if you are installing the

NI-9237 in a potentially explosive environment. Not following these guidelines may

result in serious injury or death.

Caution

 Do not disconnect I/O-side wires or connectors unless power has

been switched off or the area is known to be nonhazardous.

Caution

 Do not remove modules unless power has been switched off or

the area is known to be nonhazardous.

Caution

 Substitution of components may impair suitability for Class I,

Division 2, or Zone 2.

Caution

 The system must be installed in an enclosure certified for the

intended hazardous (classified) location, having a tool secured cover/door,

where a minimum protection of at least IP54 is provided.

ni.com

4

NI-9237 Getting Started

Содержание NI-9237

Страница 1: ...NI 9237 Getting Started 2022 07 06...

Страница 2: ...patibility Guidelines 5 Special Conditions for Marine Applications 6 Preparing the Environment 6 Connecting the NI 9237 7 Signal Descriptions 7 Connecting a Full Bridge 8 Connecting a Half Bridge 8 Co...

Страница 3: ...he documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documentatio...

Страница 4: ...ions only Follow these guidelines if you are installing the NI 9237 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnec...

Страница 5: ...zardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution Transient protection shall be provided that...

Страница 6: ...in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory...

Страница 7: ...oltage source Figure 1 NI 9237 Pinout SC AI AI RS RS EX EX T T SC 1 2 3 4 5 6 7 8 9 10 Ch0 Ch3 EX EX EX EX Ch 0 Ch 1 Ch 2 Ch 3 Caution Do not use RJ 45 cables with the NI 9237 with RJ 50 RJ 45 cables...

Страница 8: ...ge to the NI 9237 You also can connect floating signals to the NI 9237 If you connect floating signals to the NI 9237 NI recommends connecting the EX signal to the earth ground or shield for better no...

Страница 9: ...You can connect a quarter bridge to the NI 9237 by adding a resistor externally to create a half bridge Figure 4 Connecting a Quarter Bridge to the NI 9237 You also can use a quarter bridge with the...

Страница 10: ...ices to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ens...

Отзывы: