Figure 6 shows the analog output topology of the NI myRIO-1900.

Figure 6.  

NI myRIO-1900 Analog Output Circuitry

Accelerometer

The NI myRIO-1900 contains a three-axis accelerometer. The accelerometer samples each axis 
continuously and updates a readable register with the result. Refer to the 

Accelerometer

 section 

of the 

Specifications

 for the accelerometer sample rates.

DAC

DAC

DAC

DAC

0–5 V

MXP A

MXP B

AO0

AO1

AO0

AO1

DAC

DAC

M

S

P C

±10 V

AO0

AO1

DAC

DAC

A

u

dio O

u

tp

u

t

±2.5 V

Left

Right

Содержание myRIO-1900

Страница 1: ...ains pinouts connectivity information dimensions mounting instructions and specifications for the NI myRIO 1900 Figure 1 NI myRIO 1900 1 NI myRIO 1900 2 myRIO Expansion Port MXP Breakouts One Included in Kit 3 Power Input Cable 4 USB Device Cable 5 USB Host Cable Not Included in Kit 6 LEDs 7 Mini System Port MSP Screw Terminal Connector 8 Audio In Out Cables One Included in Kit 9 Button0 3 4 5 7 1...

Страница 2: ...he product is operated in the intended operational electromagnetic environment This product is intended for use in commercial locations There is no guarantee that harmful interference will not occur in a particular installation or when the product is connected to a test object To minimize interference with radio and television reception and prevent unacceptable performance degradation install and ...

Страница 3: ...r USB and wireless 802 11b g n The following figure shows the arrangement and functions of NI myRIO 1900 components Figure 2 NI myRIO 1900 Hardware Block Diagram Processor LabVIEW RT FPGA LabVIEW FPGA MXP A B MSP C x2 3 3 V UART 4 AI 2 AO 16 16 DIO DDR3 Nonvolatile Memory Wireless Wireless Button Watchdog Status LED Wireless LED 5 V 2 AI 2 AO 8 8 DIO 15 V 15 V 2 Audio Out 2 Audio In Reset Button U...

Страница 4: ...ing figure and table show the signals on MXP connectors A and B Note that some pins carry secondary functions as well as primary functions Figure 3 Primary Secondary Signals on MXP Connectors A and B 33 33 34 1 2 34 2 1 A B AO0 AO1 AGND DGND UART RX DGND UART TX DGND DIO11 ENC A DGND DIO12 ENC B DGND DIO13 DGND DGND DIO14 I2C SCL DIO15 I2C SDA 5V AI1 AI3 AI2 DIO1 DIO2 DIO3 DIO4 AI0 DIO0 DIO5 SPI C...

Страница 5: ...single ended analog output Refer to the Analog Output Channels section for more information AGND N A N A Reference for analog input and output 3 3V DGND Output 3 3 V power output DIO 0 15 DGND Input or Output General purpose digital lines with 3 3 V output 3 3 V 5 V compatible input Refer to the DIO Lines section for more information UART RX DGND Input UART receive input UART lines are electricall...

Страница 6: ...annels section for more information AO 0 1 AGND Output 10 V referenced single ended analog output channels Refer to the Analog Output Channels section for more information AGND N A N A Reference for analog input and output and 15 V 15 V power output 5V DGND Output 5 V power output DIO 0 7 DGND Input or Output General purpose digital lines with 3 3 V output 3 3 V 5 V compatible input Refer to the D...

Страница 7: ... which you can use to measure 0 5 V signals MSP connector C has two high impedance differential analog input channels AI0 and AI1 which you can use to measure signals up to 10 V The audio inputs are left and right stereo line level inputs with a 2 5 V full scale range Note For important information about improving measurement accuracy by reducing noise go to ni com info and enter the Info Code ana...

Страница 8: ...ctor C and the audio outputs share a second bus Therefore the maximum update rate is specified as an aggregate figure in the Analog Output section of the Specifications MXP connectors A and B have two analog output channels per connector AO0 and AO1 which you can use to generate 0 5 V signals MSP connector C has two analog output channels AO0 and AO1 which you can use to generate signals up to 10 ...

Страница 9: ...try Accelerometer The NI myRIO 1900 contains a three axis accelerometer The accelerometer samples each axis continuously and updates a readable register with the result Refer to the Accelerometer section of the Specifications for the accelerometer sample rates DAC DAC DAC DAC 0 5 V MXP A MXP B AO0 AO1 AO0 AO1 DAC DAC MSP C 10 V AO0 AO1 DAC DAC Audio Output 2 5 V Left Right ...

Страница 10: ...ximum Positive Reading 2047 4 883 mV 9 995 V Maximum Negative Reading 2048 4 883 mV 10 000 V For Audio In Out LSB Weight 5 V 212 1 221 mV Maximum Positive Reading 2047 1 221 mV 2 499 V Maximum Negative Reading 2048 1 221 mV 2 500 V For the accelerometer LSB Weight 16 g 212 3 906 mg Maximum Positive Reading 2047 3 906 mg 7 996 g Maximum Negative Reading 2048 3 906 mg 8 000 g DIO Lines The NI myRIO ...

Страница 11: ...n any of the following conditions when the myRIO device is starting up when the line is configured as an input when the myRIO device is powering down You can add a stronger resistor to a DIO line to cause it to float in the opposite direction UART Lines The NI myRIO 1900 has one UART receive input line and one UART transmit ouput line on each MXP connector The UART lines are electrically identical...

Страница 12: ...nes on MXP connector A You need the following items to communicate with the myRIO device over UART USB to TTL serial UART converter cable for example part number TTL 232RG VSW3V3 WE from FTD Chip Serial port terminal program configured with the following settings 115 200 bits per second Eight data bits No parity One stop bit No flow control Using the Wireless Button and LED For information about u...

Страница 13: ...form to the USB Video Device Class UVC protocol as well as machine vision cameras that conform to the USB3 Vision standard and are USB 2 0 backward compatible The NI myRIO 1900 USB host port also supports Basler ace USB3 cameras The NI myRIO 1900 USB host port also supports USB Flash drives and USB to IDE adapters formatted with FAT16 and FAT32 file systems LabVIEW usually maps USB devices to the ...

Страница 14: ...900 Physical Dimensions Figure 10 NI myRIO 1900 Dimensions Front 88 6 mm 3 49 in 0 0 mm 0 0 in 86 0 mm 3 38 in 118 2 mm 4 65 in 111 4 mm 4 38 in 104 5 mm 4 11 in 94 3 mm 3 71 in 87 5 mm 3 44 in 80 6 mm 3 17 in 73 8 mm 2 90 in 136 6 mm 5 38 in 0 0 mm 0 0 in NI myRIO ...

Страница 15: ...900 Dimensions MSP Side 1 Pin 1 44 3 mm 1 74 in 0 0 mm 0 0 in 0 0 mm 0 0 in 32 8 mm 1 29 in 112 8 mm 4 44 in 80 0 mm 3 15 in 44 2 mm 1 74 in 66 4 mm 2 61 in 22 2 mm 0 87 in NI myRIO ni com learn myrio 0 0 mm 0 0 in 0 0 mm 0 0 in 12 2 mm 0 48 in 16 4 mm 0 65 in 23 9 mm 0 94 in 35 3 mm 1 39 in 46 0 mm 1 81 in 1 19 x 3 8 mm 0 15 in ...

Страница 16: ... the NI myRIO 1900 as shown in Figure 16 Use Unified 4 or ISO M3 screws to mount the NI myRIO 1900 using the key holes Panhead screws are suitable for use with the NI myRIO 1900 key holes 1 Pin 1 0 0 mm 0 0 in 0 0 mm 0 0 in 15 4 mm 0 6 in 32 x 2 5 mm 0 10 in 2 5 mm 0 10 in 76 6 mm 3 01 in 19 4 mm 0 76 in 1 1 0 0 mm 0 0 in 0 0 mm 0 0 in 64 0 mm 2 52 in 47 0 mm 1 85 in 32 1 mm 1 26 in 20 7 mm 0 81 i...

Страница 17: ...le dimensions of the NI myRIO 1900 as a guide Refer to Figure 11 for NI myRIO 1900 key hole dimensions Leave a minimum spacing of 2 8 mm 0 11 in between the flat surface and the screw heads 2 Place the NI myRIO 1900 on the screw heads 3 Slide the NI myRIO 1900 down to secure the key holes on the screw heads 1 Place the panel on the back of the NI myRIO 1900 2 Slide the panel up to line up the scre...

Страница 18: ...crews appropriate for the surface The following figure shows the dimensions of the NI myRIO 1900 with the panel mounting kit installed Figure 18 Dimensions of NI myRIO 1900 with Panel Mounting Kit 182 5 mm 7 19 in 71 2 mm 2 81 in 228 6 mm 9 00 in 57 2 mm 2 25 in 4 x Ø 4 4 mm 0 18 in 4 x Ø 6 4 mm 0 25 in NI myRIO ...

Страница 19: ...nd Specifications National Instruments 19 Use a cable tie to secure the power and USB cables to the panel mounting kit as shown in Figure 19 Figure 19 Securing the Power and USB Cables to the Panel Mounting Kit NI myRIO BUTTON0 ...

Страница 20: ... the lifespan of the nonvolatile memory and about best practices for using nonvolatile memory go to ni com info and enter the Info Code SSDBP FPGA FPGA type Xilinx Z 7010 Wireless Characteristics Radio mode IEEE 802 11 b g n Frequency band ISM 2 4 GHz Channel width 20 MHz Table 5 Accessories Available from NI Accessory Description NI Part Number Power supply Power supply for NI myRIO 1900 723403 0...

Страница 21: ... ended channels per connector Input impedance 500 kΩ acquiring at 500 kS s 1 MΩ powered on and idle 4 7 kΩ powered off Recommended source impedance 3 kΩ or less Nominal range 0 V to 5 V Absolute accuracy 50 mV Bandwidth 300 kHz MSP connector Configuration Two differential channels Input impedance Up to 100 nA leakage powered on 4 7 kΩ powered off Nominal range 10 V Working voltage signal common mo...

Страница 22: ...P connector Configuration Two single ended channels Range 10 V Absolute accuracy 200 mV Current drive 2 mA Slew rate 2 V μs Audio output Configuration One stereo output consisting of two AC coupled single ended channels Output impedance 100 Ω in series with 22 μF Bandwidth 70 Hz to 50 kHz into 32 Ω load 2 Hz to 50 kHz into high impedance load Digital I O Number of lines MXP connectors 2 ports of 1...

Страница 23: ...m frequencies for secondary digital functions SPI 4 MHz PWM 100 kHz Quadrature encoder input 100 kHz I2C 400 kHz UART lines Maximum baud rate 230 400 bps Data bits 5 6 7 8 Stop bits 1 2 Parity Odd Even Mark Space Flow control XON XOFF Accelerometer Number of axes 3 Range 8 g Resolution 12 bits Sample rate 800 S s Noise 3 9 mgrms typical at 25 C Power Output 5 V power output Output voltage 4 75 V t...

Страница 24: ... with the NI myRIO 1900 Power supply voltage range 6 16 VDC Maximum power consumption 14 W Typical idle power consumption 2 6 W Environmental To meet these specifications you must operate the NI myRIO 1900 with the window facing away from the mounting surface and ensure that there is at least 1 in of clearance in front of the window during use Ambient temperature near device IEC 60068 2 1 IEC 6006...

Страница 25: ...ectromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55022 CISPR 22 Group 1 Class A emissions EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions AS NZS CISPR 22 Group 1 Class A emissions FCC 47 CF...

Страница 26: ...ling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Regulatory Information United States FCC Radio Exposure The radiated output power of this device is below the FCC radio frequency exposure limits Nevertheless this device should be used in s...

Страница 27: ...vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by taking one or more of the following measures Reorient or relocate the receiving antenna of the equipment experiencing the interference Increase the distance between the wireless adapter and the equipment experiencing the interference Connect the equipment to an ...

Страница 28: ...ence notamment les interférences qui peuvent affecter son fonctionnement Conformément aux réglementations d Industry Canada les émetteurs radio de cet appareil ne peuvent fonctionner qu à l aide d une antenne dont le type et le gain maximal ou minimal pour ces émetteurs transmetteurs sont approuvés par Industry Canada Pour réduire le risque d interférence éventuelle pour les autres utilisateurs le...

Страница 29: ...iva 1999 5 CE Ελληνική Greek Ε ΤΗ Α ΥΣΑ National Instruments Η Ω Ε Τ NI myRIO 1900 ΣΥ ΦΩ ΕΤΑ Σ Τ Σ ΥΣ Ω Ε Σ Α Α ΤΗΣΕ Σ Α Τ Σ ΕΣ ΣΧΕΤ ΕΣ ΑΤΑ Ε Σ ΤΗΣ ΗΓ ΑΣ 1999 5 Ε Français French Par la présente National Instruments déclare que l appareil NI myRIO 1900 est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Italiano Italian Con la presente National ...

Страница 30: ...al Instruments týmto vyhlasuje _e NI myRIO 1900 spĺňa základné po_iadavky a všetky príslušné ustanovenia Smernice 1999 5 ES Suomi Finnish National Instruments vakuuttaa täten että NI myRIO 1900 tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Svenska Swedish Härmed intygar National Instruments att denna NI myRIO 1900 står I över...

Страница 31: ...de causar interferência a sistemas operando em caráter primário Warranty For customers other than private individual users in the EU The NI myRIO 1900 is warranted against defects in materials and workmanship for a period of one year from the date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace equipment that proves to be defect...

Страница 32: ...ve access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product sa...

Отзывы: