background image

 

 

 2 

Panel Layout 

V1, V2 INPUTS: 12-45 VDC

RS-232 CONSOLE

------

ON

OFF

MASTER

COUPLER

TURBO
RING

PWR2

4

3

2

1

PWR2

RELAY2

RELAY1

D

I

1

D

I

1

V2-

V2+

I

1

V1-

V1+

I

2

Top Panel View

1

2

3

4

1

Rear Panel View

2

16

15

15

5

2

Front Panel View

7

6

8
9

11

10

12

13

14

14

2

M

N

S

A

N

N

I

TIO

R

T U

T

L

A

EN S

NI  MES-3980

Managed Ethernet Switch

MASTER

COUPLER

PWR1

PWR2

FAULT

8

7

6

4

2

5

3

1

 
 

1. Grounding 

screw 

2. 

Terminal block for power input 

PWR1/PWR2 and relay output 

3. 

Heat dissipation orifices 

4. Console 

port 

5. DIP 

switches 

6. 

Power input PWR1 LED   

7. 

Power input PWR2 LED 

8. Fault 

LED 

9. Master 

LED 

10. Coupler LED 

11.  TP port’s 100 Mbps LED 

12.  TP port’s 10 Mbps LED 

13. Model Name 

14. 10/100BaseT(X) ports 

15.  Screw hole for wall mounting kit

16. DIN-Rail kit

 

Содержание MES-3980

Страница 1: ...NI MES 3980 Hardware Installation Guide First Edition Sept 2007 P N 1802508100110...

Страница 2: ...TOS DiffServ to increase determinism y Supports 802 3ad LACP for optimum bandwidth utilization y Port Trunking for optimum bandwidth utilization y RMON for efficient network monitoring and proactive c...

Страница 3: ...O R T U T L A EN S NI MES 3980 ManagedEthernetSwitch MASTER COUPLE R PWR1 PWR2 FAULT 8 7 6 4 2 5 3 1 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation or...

Страница 4: ...N Rail attachment plate should already be fixed to the back panel of the NI MES 3980 when you take it out of the box If you need to reattach the DIN Rail attachment plate make sure the stiff metal spr...

Страница 5: ...he keyhole shaped apertures of the Wall Mounting Plates Do not screw the screws in completely leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Onc...

Страница 6: ...ENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Relay Contact The NI MES 3980 has two sets of relay output relay 1 and relay 2 Each r...

Страница 7: ...g the Digital Inputs The NI MES 3980 unit has two sets of digital inputs DI 1 and DI 2 Each DI consists of two contacts of the 6 pin terminal block connector on the NI MES 3980 s top panel The remaini...

Страница 8: ...Connector RJ45 Connector Tx Tx Rx Rx Rx Rx Tx Tx Tx Tx Rx Rx Switch Port NIC Port Cable Wiring 3 1 6 2 1 3 2 6 Rx Rx Tx Tx Relay Contact The NI MES 3980 has two relay contacts located on the top pane...

Страница 9: ...each DIP Switch is OFF The following table explains the effect of setting the DIP Switches to the ON positions DIP Switch Setting Description Serves no function reserved for future use On Enables the...

Страница 10: ...f Power is not being supplied to power input PWR2 On When 1 a relay warning event is triggered 2 the NI MES 3980 is the Master of this Turbo Ring and the Turbo Ring is broken or 3 start up failure FAU...

Страница 11: ...ng and Filtering Rate 148810 pps Processing Type Store and Forward Flow Control IEEE802 3x flow control back pressure flow control Interface RJ45 Ports 10 100BaseT X auto negotiation speed F H duplex...

Страница 12: ...award winning National Instruments Web site for software drivers and updates a searchable KnowledgeBase product manuals step by step troubleshooting wizards thousands of example programs tutorials ap...

Страница 13: ...opac ExpresswayAustin Texas 78759 3504USATel 512 683 0100 Worldwide Offices Australia 1800 300 800 Austria 43 662 457990 0 Belgium 32 0 2 757 0020 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 2...

Отзывы: