![NI DAQPad-MIO-16XE-50 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/ni/daqpad-mio-16xe-50/daqpad-mio-16xe-50_user-manual_1685652050.webp)
Chapter 3
Connecting the Signals
©
National Instruments Corporation
3-21
DAQPad-MIO-16XE-50 User Manual
Analog Output Signal Connections
The AO signals are DAC0OUT, DAC1OUT, and AOGND.
DAC0OUT is the voltage output signal for AO channel 0. DAC1OUT is the
voltage output signal for AO channel 1.
AOGND is the ground-reference signal for both AO channels and for the
external reference signal.
Figure 3-9 shows how to make AO connections and the external reference
input connection to the DAQPad-MIO-16XE-50.
Figure 3-9.
AO Connections
DAC0OUT
AOGND
Channel 0
Channel 1
Analog Output Channels
I/O Connector
DAC1OUT
VOUT 0
VOUT 1
Load
Load
+
–
+
–