NI cRIO-9082 Скачать руководство пользователя страница 2

potentially explosive environment. Not following these guidelines may result in serious injury
or death.

Caution

 

Do not disconnect the power supply wires and connectors from the

controller unless power has been switched off.

Caution

 

Do not disconnect I/O-side wires or connectors unless power has been

switched off or the area is known to be nonhazardous.

Caution

 

Do not remove modules unless power has been switched off or the area is

known to be nonhazardous.

Caution

 

Substitution of components may impair suitability for Class I, Division 2.

Caution

 

For Division 2 and Zone 2 applications, install the system in an enclosure

rated to at least IP54 as defined by IEC/EN 60079-15.

Caution

 

The USB port requires the NI Industrial USB Drive with Retention Screw

(780717- 

xxxx

) for hazardous locations. Do not disconnect a drive unless the

cRIO-9082 is powered off or the area is known to be nonhazardous.

Special Conditions for Hazardous Locations Use in Europe and
Internationally

The cRIO-9082 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07
ATEX 0626664X and is IECEx UL 14.0089X certified. Each device is marked   II 3G and is
suitable for use in Zone 2 hazardous locations, in ambient temperatures of 0 °C ≤ Ta ≤ 55 °C.

Caution

 

You must make sure that transient disturbances do not exceed 140% of

the rated voltage.

Caution

 

The system shall only be used in an area of not more than Pollution

Degree 2, as defined in IEC/EN 60664-1.

Caution

 

The system shall be mounted in an ATEX/IECEx-certified enclosure with

a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.

Caution

 

The enclosure must have a door or cover accessible only by the use of a

tool.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.

2

  | 

ni.com

  | 

NI cRIO-9082 Getting Started Guide

Содержание cRIO-9082

Страница 1: ...this document Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to NI for...

Страница 2: ...urope and Internationally The cRIO 9082 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14 0089X certified Each device is marked II 3G and is suitable for...

Страница 3: ...cation for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applicat...

Страница 4: ...evice with Power Connector 2 Ferrite 3 cRIO Device Drivers Media 4 Getting Started Guide Installing Software on the Host Computer Before using the cRIO 9082 you must install the following application...

Страница 5: ...e C Series module 3 Align the C Series module with a slot and seat it in the slot until the latches lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on...

Страница 6: ...the grounding electrode system of the facility What to Use Ring lug Wire 1 6 mm2 14 AWG or larger Screwdriver Phillips 2 What to Do Complete the following steps to ground the cRIO 9082 1 Attach the r...

Страница 7: ...a primary power input V1 and a secondary power input V2 The POWER LED on the cRIO 9082 indicates which power input is in use as shown in the following table Table 1 POWER LED Indicators LED Color LED...

Страница 8: ...m 2 in to 3 in between the ferrite and the end of the leads 2 Close the ferrite around the leads 3 Remove the power connector from the cRIO 9082 Caution Do not tighten or loosen the terminal screws on...

Страница 9: ...g the cRIO 9082 to a Network Connect the cRIO 9082 to an Ethernet network using RJ 45 Ethernet port 1 on the controller front panel Use a standard Category 5 CAT 5 or better shielded twisted pair Ethe...

Страница 10: ...the IP Settings section then click Apply Note For information about configuring network settings refer to the Configuring Network Settings book of the MAX Remote Systems Help In MAX click Help Help To...

Страница 11: ...settings When you reboot the controller with the IP RESET switch in the ON position the controller attempts to connect to the network using DHCP If the controller is unable to obtain an IP address it...

Страница 12: ...Modify the VI as necessary to solve the memory usage issue Continuously Flashing The chassis has detected an unrecoverable error Contact National Instruments Continuously Flashing or Solid The device...

Страница 13: ...extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you receive important information updates fro...

Страница 14: ...You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export...

Отзывы: