NI CB-68LP/CB-68LPR User Guide
|
© National Instruments
|
3
3.
Connect the CB-68LP/CB-68LPR(s) to the DAQ device using the appropriate cable(s) for
your device.
4.
Launch Measurement & Automation Explorer (MAX). In the left panel, expand
Devices
and Interfaces
to confirm that your DAQ device is recognized, and then configure your
device settings.
5.
Test specific device functionality. Run a Test Panel in MAX by right-clicking your DAQ
device and selecting
Test Panels
. Click
Start
to test the device functions.
When you have finished using the CB-68LP/CB-68LPR, power off any external signals
connected to the CB-68LP/CB-68LPR before you power off your computer.
Specifications
These specifications are typical at 25 °C unless otherwise noted.
Caution
Do
not
connect hazardous voltages (>30 V
rms
/42 V
pk
/60 VDC) to the
CB-68LP/CB-68LPR.
Physical Characteristics
Dimensions
CB-68LP ................................................... 143.5 mm × 107.4 mm × 30.0 mm
(5.65 in. × 4.23 in. × 1.18 in.)
CB-68LPR ................................................ 167.6 mm × 76.2 mm × 29.2 mm
(6.60 in. × 3.00 in. × 1.15 in.)
Weight
CB-68LP ................................................... 155 g (5.4 oz)
CB-68LPR ................................................ 162 g (5.7 oz)
I/O connector .................................................... One 68-pin male SCSI connector
Screw terminals ................................................ 68, all I/O signals are available at screw
terminals
Wire gauge................................................ 0.0509 to 3.31 mm
2
(12 to 30 AWG)
Torque ....................................................... 0.5 N · m (4.4 lb · in.)
Clean the hardware with a soft, nonmetallic brush.