background image

NI CB-2162 User Guide

22

ni.com

Caution

When connected to other test objects, this product may cause radio interference. 

In a residential environment, the user may be required to take adequate measures to reduce 
the radio interference.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of their life cycle, all products 

must

 be sent to a WEEE recycling 

center. For more information about WEEE recycling centers and National Instruments 
WEEE initiatives, visit 

ni.com/environment/weee.htm.

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20,  Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 6555 7838, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11,  France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, India 91 80 41190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, 
Korea 82 02 3451 3400,  Lebanon 961 0 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 0800 553 322, 
Norway 47 0 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 095 783 68 51, 
Singapore 1800 226 5886, Slovenia 386 3 425 4200, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 0 8 587 895 00,  Switzerland 41 56 200 51 51, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
United Kingdom 44 0 1635 523545

Содержание CB-2162

Страница 1: ...els Connect to other devices for testing and debugging Develop and interface to prototype circuits Probe DIO and control channels This guide explains how to set up and use the NI CB 2162 single ended...

Страница 2: ...resistor networks for pull up pull down and series termination The NI CB 2162 ships populated with a 0 resistor A 50 resistor also is included for optional STROBE PFI 5 series termination 30 gauge wi...

Страница 3: ...d be the first thing you read Its purpose is to guide you through setting up the digital waveform generator analyzer module and configuring it to generate or acquire your first samples Help This onlin...

Страница 4: ...r Diagram 1 68 Pin Digital Data Control DDC Connector 2 Termination Sockets 3 Control and Ground Header Pairs 4 Prototyping Area Power Connectors 5 Prototyping Area Power LED 6 Prototyping Area Power...

Страница 5: ...isconnect power from the module accessory and any other connected hardware to prevent damage to the hardware and personal injury NI is not liable for damage resulting from improper connections 1 Insta...

Страница 6: ...n the cable connector 3 Attach the other end of the cable assembly to the DDC connector of the NI CB 2162 and secure them together with the captive screws on the cable connector Connecting Signals Eac...

Страница 7: ...vice 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34...

Страница 8: ...ns that exceed any of the maximum ratings for the NI CB 2162 or the NI digital waveform generator analyzer module can damage the module and the computer Maximum input ratings are provided in the Speci...

Страница 9: ...assembly Note Header receptacle assemblies are not included with the NI CB 2162 but you can create custom assemblies by purchasing parts from vendors such as 3M Connectivity is made by inserting the r...

Страница 10: ...and quality can dramatically affect how well the signal integrity is maintained NI recommends using short twisted pair ribbon cables Refer to the device or cable manufacturer for additional informati...

Страница 11: ...he wire wrap tool Place the wire wrap tool over the appropriate header pair pin and twist the tool around the header post You then can make connections to the device under test DUT as defined by the d...

Страница 12: ...the effect of stubs termination is placed at the end of the signal path If your signal transmission line ends on the NI CB 2162 you can use the provided termination socket If your signal terminates s...

Страница 13: ...th jumpers W 4 7 in place pin 1 of J13 J15 J17 and J19 are all pulled to ground The signal can be alternately pulled up or terminated to a nonground voltage if you remove the jumpers and apply power t...

Страница 14: ...n Figure 7 Connect external power to this solder point Refer to the resistor network manufacturer documentation for information on proper pin labeling and resistor values Terminating Control Channel S...

Страница 15: ...s to your device under test are matched in length When inserting a resistor into any of the control channel termination sockets first trim the leads of the resistor to an appropriate length and ensure...

Страница 16: ...not light The power connectors and LED for the prototyping area are labeled in Figure 1 Prototyping Circuits The prototyping area of the NI CB 2162 consists of 304 through hole solder pads 208 isolat...

Страница 17: ...he standoffs that are required to attach the NI CB 2162 to the bottom of the CA 1000 If you want to rack mount the NI CB 2162 after it is installed in the CA 1000 you can purchase rack mount side pane...

Страница 18: ...rew the standoffs onto the threaded screws in the locations shown in Figure 12 5 Position the NI CB 2162 on the standoffs of the CA 1000 6 Secure the NI CB 2162 in the bottom of the CA 1000 using two...

Страница 19: ...tte with one of the panhead screws included with the CA 1000 kit 10 Reattach the DDC connector jackscrews through the opening in the I O panelette Figure 12 Secure the NI CB 2162 and Attach the I O Pa...

Страница 20: ...unused panelette openings as shown in Figure 13 The panelettes in the following figure are blank but you can purchase many other types of I O panelettes from NI For more information on the other I O...

Страница 21: ...0 mA forward current Prototyping Area Dimensions 4 9 cm 1 57 3 54 in Solder pads 208 unconnected 48 ground 48 VCC Traces Type Matched length to 100 mils AC impedance 50 Power External DC power supply...

Страница 22: ...as offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or d...

Страница 23: ...l Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the ap...

Отзывы: