-60
©
National Instruments Corporation
Configure and Install Your NEC-GPIB/TNT
60
Set the NEC-GPIB/TNT Shield Ground Configuration
The NEC-GPIB/TNT is set at the factory with the jumper in place to connect the logic ground of the
NEC-GPIB/TNT to its shield ground. This configuration minimizes EMI emissions.
Note
The NEC-GPIB/TNT was tested for compliance with FCC standards with the shield ground
connected to logic ground. Removing the jumper might cause EMI emissions to exceed any or all
of the applicable standards.
Most users do not need to change the shield ground configuration. If you feel you must disconnect
the logic ground from shield ground, follow these steps:
1. Locate the shield ground jumper W1 on the NEC-GPIB/TNT. (View the
2. Remove the jumper and place it across only one of the jumper pins, as shown in the following
figure.
Figure 12.
NEC-GPIB/TNT Ground Configuration Jumper Settings
a. Logic Ground Connected to Shield Ground (Default)
b. Logic Ground Disconnected from Shield Ground
W1
W1