![NI 9866 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ni/9866/9866_operating-instructions-manual_1685497009.webp)
NI 9866 Operating Instructions
8
ni.com
Termination Resistors
LIN cables require no termination, as nodes are terminated at the
transceiver. Slave nodes typically are pulled up from the LIN bus
to VBat with a 30 k
Ω
resistance and a serial diode. This
termination usually is integrated into the transceiver package. The
master node requires a 1 k
Ω
resistor and serial diode between the
LIN bus and VBat. On NI-XNET LIN products, master
termination is software selectable; you can enable it in the API
with the NI-XNET Session Interface:LIN:Termination property.
NI 9866 Hardware Overview
The NI 9866 has one full-featured LIN port that is isolated from
the other modules in the system. The port has a LIN controller
that is fully compliant with the LIN 1.3/2.0/2.1/2.2 Specification.
The port also has an NXP TJA1028 LIN transceiver that is fully
compatible with the LIN 1.3/2.0/2.1/2.2 and SAE J2602 standard
and supports baud rates up to 20 kbps.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com