background image

• reinstall the fuse holder

Always replace the fuse with one of the exact same
specifications. 

Ten:

For systems operating at 115 volts, use only a 5x20 mm,
T3A, 250-volt  slow-blow fuse. 

For systems operating at 230 volts, use only a 5x20 mm,
T2.0A, 250-volt  slow-blow fuse.

Twelve:

For systems operating at 115 volts, use only a 5x20 mm,
T5A, 250-volt  slow-blow fuse. 

For systems operating at 230 volts, use only a 5x20 mm,
T2.5A, 250-volt  slow-blow fuse.

Troubleshooting

If the Ten or Twelve fails to operate at all when the Power
Switch is turned on, thoroughly check the power cord,
input and output connections 

If the Ten or Twelve turns on but the LED indicator fails
to illuminate, mis-wiring or a power surge may have
caused the protection fuse to blow. Replace it with one of
correct type and value. 

If the Ten or Twelve turns on but its status LED stays red,
the unit is gone into protect mode, which could be
caused by incorrect wiring, short circuits, or excessive
volume. Turn off the Power Switch on the subwoofer for
two or more seconds to reset, and double check all
speaker cables to be sure that no small metal strands are
shorting the terminals.

If the Ten or Twelve subwoofer has a 

loud hum

when

you turn it on.  The following is what you can I do to get
rid of the hum;

The DSS system and all cable TV systems have a
ground wire connected to the shield of the signal on the
outside of the house and driven into the earth with a
metal rod or water pipe. The Ten and Twelve is ground-
ed to the power outlet through the third prong of the
power cord. The AC wiring in the building has the ground
conductor connected to a metal rod or water pipe outside
the building. Once a patch cord is connected between
the DSS system and the subwoofer, a complete circuit is
formed called a ground loop. Current flowing in the
ground loop can cause very large amounts of noise in the
system.

Operation

We recommend that the Ten or Twelve power be left on,
which will allow the built-in Auto Mode feature to disable
the subwoofer when not in use.

Every speaker, has limits, and it's important to listen for
them. Speaker damage most often results not from brief
loud musical peaks, but from sustained high volume
levels in some or all frequencies.  For this  reason,
extreme volume settings and excessive bass, treble or
equalizer boosts are not recommended.

If you hear unusual distortion or breakup, or notice heat
coming from the woofer, decrease volume immediately,
neutralize any excess bass, treble or equalizer boosts,
and avoid setting any controls to similar extremes again.

Maintenance

Your Ten and Twelve is designed for years of use with no
or minimal maintenance, as long as you avoid exposing
it to direct sunlight, high temperatures, or moisture.
Clean cabinets, when necessary, using a damp cloth or
a mild, non-abrasive cleaner; to clean grilles, remove
from speaker and use a soft brush or a vacuum on its
lowest setting.   Do not attempt to clean the actual
driver.

Changing the Line Voltage Setting

The Ten and Twelve were designed to operate on two

line voltage settings, 115VAC and 230VAC.  In the event

that it is necessary to change the line voltage setting,

begin by turning the power switch to the off position.

Remove all the connections from the amplifier, including

the detachable power cord.  Using a flat blade screw-

driver, slide the switch to the correct position.  Use the

115VAC position for 110 to 120 VAC, and the 230VAC

position for 220 to 240 VAC.  Next you will likely need a

power cord that fits the AC receptacle and you will need

to replace the fuse (see "Changing the Fuse" below)

Changing the Fuse

The Ten and Twelve amplifier's fuse is user-serviceable.

To replace it:

• turn the power OFF 

• unplug the power cord

• remove the fuse holder cover (above to the power inlet)

with a flat blade screwdriver 

• remove the fuse from the holder and replace it with the

appropriate type. 

Содержание Classic Ten

Страница 1: ...Classic Powered Subwoofers Ten Twelve Owners Manual...

Страница 2: ...can result in a risk of fire or electric shock 14 CLEANING Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 15 NON...

Страница 3: ...boundaries such as walls rein force a speaker s bass output 3dB for two walls 6dB for a corner if the subwoofer is placed near them Conversely placing a subwoofer out in the room results in a relativ...

Страница 4: ...ODE This feature automatically switches your Ten or Twelve into minimum power mode ie sleep whenever no signal is present for 20 minutes When a signal is received it immediately turns on again As AUTO...

Страница 5: ...Switch Selects response mode of subwoofer depending on placement 6 Subwoofer Phase Selector 2 position selectable phase control for subwoofer 0 180 7 Line Input Low level RCA input jacks for L R signa...

Страница 6: ...romise its output to the L R speakers If you find that your receiver will not accommodate more than one cable per output terminal check with your NHT dealer for alternative methods of connection With...

Страница 7: ...OLUME CONTROL settings and then PHASE SELECTOR Frequency Chart Low Bass Mid Bass Upper Bass Lower Mid Mid Upper Mid High Below 50Hz 50Hz 100Hz 100Hz 180Hz 3K and above 180Hz 300Hz 300Hz 700Hz 700Hz 3K...

Страница 8: ...very large amounts of noise in the system Operation We recommend that the Ten or Twelve power be left on which will allow the built in Auto Mode feature to disable the subwoofer when not in use Every...

Страница 9: ...ont L R channel speakers some times referred to as satellites Main In A line level RCA XLR power amplifier input on To legally install cable TV or a DSS system there must be a ground conductor from th...

Страница 10: ...amplifier or preamplifier Receiver A preamplifier amplifier and tuner built into one chassis Satellite Front L R speakers when used with a sub woofer Also referred to as main speakers Sensitivity A r...

Страница 11: ...nts that if it fails to function properly due to a manufacturing defect despite its being installed and operated according to these instruc tions and used under normal conditions it will be either rep...

Отзывы: