S05-LW User’s Manual
8
8 ZigBee Reset
In the case where the parent devices (coordinator, gateway, or router) for S05-LW are no longer
available or have been reset, S05-LW will need to be reset by applying a 5-second press to the link
switch, the green & red LEDs will both come on during the reset, then the green LED should show
ready to join
status (flash once every second).
Recommendation:
It is strongly recommended to remove the batteries immediately from S05-LW
once it has been reset as this will prevent damage and greatly improve battery life.
9 Product Specifications
Measuring Element
Leaf wetness sensor
Wireless Protocol
Compliant IEEE 802.15.4, ZigBee2007 / PRO HA Profile
Operating Frequency
2.4GHz ISM band
Transmission Range
500m (1640ft) line of sight
RF Output Power
18dBm
Power Supply
DC 6 V 4
x
AA alkaline batteries
Operating Environment
-40 ~ +125°C, < 85% relative humidity
Power Consumption
TX: 200mA, Sleep: 6µA
Measurement Accuracy
Temperature: ±0.5°C, Humidity: ±4.5%
Network Topology
Star / Tree / Mesh
Transmit Interval
1 second to 75 minutes, based on DIP switch setting
Battery Life
> 1 year @ 10-minute transmission interval (dependent on battery quality)
Enabling Devices
Coordinator
WZB-01USBC / WZB-02485C
Gateway
G07-W / WZB-05ET
Router
S05-R / WZB-01USBR / WZB-02485R
Dimensions
130 (H) x 50 (Φ) mm / 5.1 (H) x 1.9 (Φ) inches
Weight
142.8g / 5.04oz
Supported Systems
Windows NT ~ Win 8
Certifications
CE / FCC