2.7 Simple Operation Check
DP Series
27
2.7 Simple
Operation
Check
This section describes how to perform a simple operation check when you purchased a new product,
or after storing the product for a long period. This check should be performed without load. For a
polyphase system, remove the System Cable, and check the single-phase output for each cabinet. If
you are not satisfied with the results verified at the operation check, please request the repair to us or
our agent.
Operation procedure
1.
Connect the power supply referring to "
2.4 Grounding and Power Connections
."
2.
Attach the resin-molded output terminal cover and the output cable holder without connecting
anything to the output terminals or any other terminal/connector.
OUTPUT
Hi
Lo
Nothing is connected to
the output terminal.
3.
«Only for Multi-phase model» For the Multi-phase model, set the phase mode setting switch
according to the output phase mode to be checked.
1
φ
2W
1
φ
3W
3
φ
4W
スイッチをスライドさせて設定す
Set the switch by sliding it.
Содержание DP015S
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Страница 4: ......
Страница 18: ......
Страница 19: ...DP Series 1 1 Outline 1 1 Overview 2 1 2 Series Line up and Polyphase System Configuration 2 1 3 Features 4 ...
Страница 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Страница 215: ...DP Series 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202 ...
Страница 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Страница 225: ...DP Series 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 214 ...
Страница 237: ...7 8 Replacement Air Filter DP Series 219 フロントグリル フロントグリル Front grill 1 Front grill 2 Figure 7 2 Front Grills ...
Страница 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Страница 239: ...DP Series 221 8 Troubleshooting 8 1 Error Messages and Error Handling 222 8 2 When a Failure is Suspected 229 ...
Страница 298: ......
Страница 300: ......
Страница 302: ......
Страница 303: ......
Страница 304: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN ...