10
2 First start (only in a Nexus Network)
2.1 Initialising the instrument
At power on, the instrument will perform a self test. The display will first
show all segments, then the software version number and the Nexus
Network ID number.
At first power on after installation, you will be asked to press
KEY
[PrSKEY]. This will give the instrument a logical ID number on the Nexus
Network.
To initialise the instrument, press
KEY
on all installed digital instruments,
one at the time.
Note: Always wait for the text ”Init OK”
to be displayed, before you press KEY
on the next instrument!
The Server automatically gives the first unit ID number 16, then 17 and
so on. The order in which you press
KEY
is the same order as the
instruments will be given a logical ID number on the Nexus Network.
The example shows that the instrument version number is 1.00 and the
given logical ID number is 16.
2.2 Re-initialising the instrument
If two instruments by mistake have the same ID number, this can cause
disturbance and block the information on the Nexus data bus.
To re-initialise the instrument, press
DOWN
and
UP
together during the
power up sequence when version and ID numbers are displayed.
The display self test is then re-started on all instruments and you will be
asked to press
KEY
on each instrument as explained above.
Note!
If you do not succeed to re-initialise, we suggest you disconnect all
but one instrument with the same ID number, then repeat the above
procedure.