Make any required Zone configuration changes and then click the Apply button to
implement these changes and store these settings. The Apply button will only become
active for valid configurations.
Output Configurations
The U74 amplifier can be configured in a variety of mono or stereo Single-Ended or
mono or stereo Bridge-Tied-Load formats. It is also possible to mix zone modes.
Mono
In basic mono configuration, each speaker output is an independent mono signal and
each connects to a separate speaker.
The zone configuration for this mode is:
Volume and Tone controls are independent for all 8 zones.
The speaker wiring for this mode is as follows:
4Ω
1, 3,
5, 7
2, 4,
6, 8
4
Ω