Nexus EN-7P Скачать руководство пользователя страница 7

12

13

How to Use

1. POWER UP YOUR IONIZER.

- Depress the black power button located on the back of the ionizer to the 

  "ON" position.

- The black power button is ALWAYS left on. Your ionizer will "go to sleep" in 

   between uses and "wake up" when it detects water flow again.  

- You will hear a single chime and the display panel will illuminate for 2-3 seconds.

- With the power on and the display panel dark, your ionizer is now in standby mode.  

2. START WATER FLOW THROUGH YOUR IONIZER 

   

A. Set the flow control Valve   -  This control is on the front of machine 

    and has an "ON" and "OFF" position. Try initially setting this half way 

    between "ON' and "OFF". 

   

 

Important : This is one of the most critical features in controlling your 

    ionizer's performance.   

    This control WILL DIRECTLY impact the performance of your ionizer. 

    A slow flow will yield higher pH; a fast flow will yield lower pH.

B. Turn on your water faucet. Turn the lever to until you "divert" the water through your ionizer.

C. Get the feel for the difference in flow rates by adjusting FLOW CONTROL VALVE from a slow 

    trickle to the fastest flow. When you begin ionizing the water, start with it in the medium range 

    and adjust faster or slower as necessary to achieve optimum results.

    

   

3.  TO SELECT ALKALINE WATER

 

A. Start Water Flow through your ionizer. 

    Remember - 

The New ionizer cleans every times use.

    But when the ionizer is operated within 1 minute, have no cleaning.

 

B. To select an alkaline level simply depress the "ALKALINE" button to move to next 

    level until the desired level is achieved.  The pH level indicator will change accordingly.

C. Note: Your ionizer will always "remember" the last setting. For instance, if the previous 

    setting was Alkaline Level Medium, then it will go back to Medium when you start the 

    ionizer. 

IMPORTANT NOTES: 

-If you have never consumed alkaline water - do not use a setting higher than 

  LOW to begin with. Let your body adjust slowly and naturally for 4-7 days. 

  After this initial adjustment period, you may gradually increase the alkalinity of the water.

-pH levels will vary according to the minerals present in the source water and water 

  flow rate through your ionizer.

4.  TO SELECT ACIDIC WATER 

Note: Acidic water is for external use only. 

DO NOT DRINK.

1. With water running through the ionizer:

2. Depress the "ACIDIC" button. The Acidic Water Indicator will light and the pH Level 

    Indicator will move up and down the scale to indicate the selected level.

3. To select a different level, depress the "ACIDIC" button to move to next level until 

    the desired setting level is achieved. The orange symbol and number 

    will change accordingly.

Содержание EN-7P

Страница 1: ...er Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY NEXUS TECH CO LTD 362 Gwangmyeong Siboem Industrial Compl...

Страница 2: ...ontact your dealer Attempting to do so will void your valuable warranty Do not use your ionizer at voltages other than specified AC 110V FOR USA Use a GFI outlet Do not plug in your ionizer where it w...

Страница 3: ...Do not expose the pH measuring reagent to extreme heat flames or fire It is combustible Do not drink the pH reagent liquid put it in the eyes or apply to the body If the liquid is ingested induce vom...

Страница 4: ...pH FAST FLOW lower pH Key hole Slots For Wall Mounting To save counter space you can mount your ionizer on the wall Note use suitable fasteners Fuse Holder Your ionizer comes equipped with a fuse to...

Страница 5: ...r Low Water Pressure Indicator When lit this indicates insufficient operating pressure A beep sound is activated Your ionizer should not be operated when low pressure LED due to potential overheating...

Страница 6: ...astic port labelled ACIDIC WATER OUTLET on the bottom of the ionizer First slide a squeeze clamp over the end of the hose Then attach the gray hose by simply pushing it firmly over the white plastic p...

Страница 7: ...ve optimum results 3 TO SELECT ALKALINE WATER A Start Water Flow through your ionizer Remember The New ionizer cleans every times use But when the ionizer is operated within 1 minute have no cleaning...

Страница 8: ...ng the ionizer is in standby or asleep How to Reset the Filter Life When the digital filter life indicator reaches full bar it is time to replace your filter Please replace the new filter and reset th...

Страница 9: ...ween settings level 1 to 3 After setting the unit if the buttons are not pushed for another 5 seconds or if the water is run through the unit the last setting chosen is remembered Depress the ALKALINE...

Страница 10: ...dvanced filtration system You can use it both as drinking water and to take medications with Some uses for the different levels of Acidic Water Alkaline water levels Note pH levels will always vary wi...

Страница 11: ...s of the new filter Seat the large opening on the bottom of the filter cartridge onto the base Push the filter down and into the housing compartment ensuring the opening at the top of the filter is se...

Страница 12: ...Carbon GAC The workhorse of the filtration media GAC is especially effective at removing chlorine its odor and taste agricultural chemicals phenol trihalomethane and other chemical contaminants Silver...

Страница 13: ...pressure in your household plumbing The input hose is bent kinked or otherwise restricted Replace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house ma...

Страница 14: ...e center along with this warranty card for repair free of charge 2 Warranty term 24 months from a purchasing date 3 Exception to warranty Expiration of warranty terms Defect caused by a natural disast...

Отзывы: